2025 UK Decking Installation Guide

SPANNING REQUIREMENTS FOR TREX STAIRS

NOTE: Shown with timber framing.

280 mm min. depth

Stringer

5 mm gapping

20 mm max. overhang

Fasten treads to all stringers

14 mm x 184 mm Riser

Trex fascia or trim

See chart below

Riser removed for clarity

91.4 cm minimum width – 4 stringers are required Above 91.4 cm width – 5 stringers are required

MAXIMUM SPACING OF STAIR JOISTS (Center-to-Center)

Transcend 25 x 140 mm

30 cm

Enhance 25 x 140 mm

23 cm

Transcend 33 x 140 mm

30 cm

NOTE: Construction methods are always improving. Please refer to www.trex.com (and your country) for the most up-to-date installation requirements.

31