MRN_909559_2022 Marine Catalog_PRICE

Air Heaters Product Overview

See page 18

Air Top 2000 STC

Air Top Evo 40

See page 20

See page 22

Air Top Evo 55

Technical specifications

Air Top 2000 STC

Air Top Evo 40*

Air Top Evo 55**

EC approval mark ECE R122 (Heating) EC approval mark ECE R10 (EMC) Heat output, control range/boost (kW) Heat output, control range/boost (BTU/h)

E1 00 0216 E1 04 1085

E1 00 0385 E1 05 5529

E1 00 0386 E1 05 5529

0.9 – 2.0 3,000 – 7,000

1.5 – 3.5/4.0* 5,100 – 12,000/13,600* Diesel, 0.18 – 0.43/0.49* Diesel, 0.04 – 0.11/0.12*

1.5 – 5.0/5.5** 5,100 – 17,000/18,800** Diesel, 0.18 – 0.61/0.67** Diesel, 0.04 – 0.15/0.17**

Fuel, Fuel consumption (l/h) Fuel, Fuel consumption (gal/h)

Diesel, 0.12 – 0.24 Diesel, 0.03 – 0.06

Rated voltage (V)

12

12, 24

12, 24

Rated power consumption (W)

14 – 29

15 – 40/55*

15 – 95/130**

Rated current (for 12 V) (A)

1.2 – 2.4

1.3 – 3.3/4.6*

1.3 – 7.9/10.8**

Rated current (for 24 V) (A)

0.6 – 1.7/2.3*

0.6 – 4.0/5.4**

Air Flow against 0.5 mbar (m 3 /h) Air Flow against 0.5 mbar (cfm) Dimensions L x W x H (mm) Dimensions L x W x H (inch)

93 55

132/140* 77.7/ 82.4*

200/220** 117.7/ 129.4** 423 x 148 x 162 16.6 x 5.8 x 6.3

310 x 120 x 118 12.2 x 4.7 x 4.7

423 x 148 x 162 16.6 x 5.8 x 6.3

Weight (kg) Weight (lbs)

2.6 5.73 60 2.36 22 0.87

5.9 13

5.9 13

Diameter air outlet (mm) Diameter air outlet (inch) Diameter exhaust (mm) Diameter exhaust (inch)

90 3.54 24 0.94

90 3.54 24 0.94

* Boost power level for a maximum duration of 6 hrs. ** Boost power level for a maximum duration of 30 min.

15

Made with FlippingBook Online newsletter