Look, doc: no hands!

VistaPure’s patented AutoFill accessories replenish SciCan STAT IM ® and BRAVO ™ autoclaves with distilled-quality water automatically— enabling truly hands-free convenience. VistaPure AutoFill accessory kits work with all VistaPure systems and can be installed easily on any STAT IM 2000/G4 or 5000/G4, or any BRAVO autoclave, in just a few minutes!

No more purchasing and storing distilled water

No more spills while filling autoclaves manually

No more cycle-fault errors caused by forgetting to fill reservoirs

No more staff time spent filling autoclaves = more time with patients

AutoFill for STAT IM (S3020)

AutoFill for BRAVO (S3030)

scican.com

scicancanada.com

SciCan @SciCan SciCanTV

VistaPure AutoFill Installation

A 12-foot length of clear polyurethane tubing is already attached to the AutoFill manifold. If the desired distance between the connection to the VistaPure and the autoclave is greater than 12 feet, simply order a longer length of the clear polyurethane tubing, as the distance from the VistaPure to the autoclave is not limited, except by the feed tubing.

Installing AutoFill on a STAT IM The VistaPure AutoFill for STAT IM device (S3020) can be installed on any new or older model 2000 or 5000 STAT IM autoclave as follows:

Manual Autoclave Wand

AutoFill Manifold & Float

Shut-O Valve

Flow Control

Tee

VistaPure

STAT IM

Installing AutoFill on a BRAVO The VistaPure AutoFill for BRAVO device (S3030) can be installed on any model BRAVO autoclave. In order to connect the VistaPure AutoFill to the BRAVO, one of the two tanks that come with the BRAVO must be selected as a “relay tank” since the BRAVO system uses a suction-lift pump to fill its reservoir when in its automatic-filling mode. Note that the relay tank must be located within 6 feet of the BRAVO unit, due to the suction-lift capacity of the BRAVO pump.

If using the small BRAVO tank:

Manual Autoclave Wand

Silicone Tubing to BRAVO

AutoFill Manifold & Float

Shut-O Valve

Flow Control

Suction Fitting

Tee

VistaPure

If using the large BRAVO tank:

AutoFill Manifold & Float

Manual Autoclave Wand

Shut-O Valve

Flow Control

NOTE: If using the large BRAVO relay tank, you must install the included extension rod

Tee

between the manifold and the float assembly.

VistaPure

Silicone Tubing to BRAVO

SciCan Ltd. 1440 Don Mills Rd Toronto, ON M3B 3P9 CANADA Distributed by:

Vista Research Group PO Box 321 Ashland, Ohio 44805-0321 USA Manufactured by:

Phone (419) 285-3927 VistaResearchGroup.com

Toll Free (800) 667-7733 Phone (416) 445-1600 Fax (416) 445-2727 customerservice@scican.com

scican.com

scicancanada.com

SciCan @SciCan SciCanTV

Page 1 Page 2

Made with FlippingBook Digital Publishing Software