UNUSUAL APPLICATIONS
RECOMMENDED LOAD FACTORS FOR UNUSUAL SLINGING METHODS AND CONDITIONS
L FACTOR NORMAL Y APPLIED TO WLL OF A SINGLE CHAIN.
0.8
2.0
1.3
UNEVEN LOAD DISTRIBUTION
The factor is applicable to WLL of a standard double branch sling
1.6
0.7
TEMPERATURE LOADING: Applicable to chain temperature
200ºC - 300ºC 0.9
300ºC - 400ºC 0.75
0ºC - 200ºC 1.0
EDGE LOADING: Applicable to load lifting and load lashing
r
r
r = more than 2 x chain size
r = more than chain size
Sharp corners
NOT RECOMMENDED WITHOUT CORNER PROTECTION
0.7
1.0