SHORT LINK CHAIN GRADE 5&6

DIMENSIONS (mm)

FORCES

APPROX MASS (kg/m)

PRODUCT CODE

PITCH (P)

DIAMETER (dn)

WLL (t) 0.72 0.79 0.98 1.28 1.62 2.00 2.51 3.38 3.92 5.12 8.01 9.69 13.5

G MAX

W2w MAX 22.2 23.3 25.9 29.6 33.3 37.0 41.4 48.1 51.8 59.2 74.0 81.4 96.2

dw MAX

MPF (kN) 14.1 15.6 19.2 25.1 31.8 39.3 49.3 66.4 77.0 101 157 190 265

BF (kN)

W2 MAX 21.9 23.0 25.6 29.2 32.9 36.5 40.9 47.5 51.1 58.4 73.0 80.3 94.9

W1 MIN 7.8 8.2 9.1

NOM 18.0 18.9 21.0 24.0 27.0 30.0 33.6 39.0 42.0 48.0 60.0 66.0 78.0

NOM 6.0 6.3 7.0 8.0 9.0 10.0 11.2 13.0 14.0 16.0 20.0 22.0 26.0

TOL ± 0.24 0.25 0.28 0.32 0.36 0.40 0.45 0.52 0.56 0.64 1.00 1.10 1.30

MIN 17.5 18.3 20.4 23.3 26.2 29.1 32.6 37.8 40.7 46.6 58.2 64.0 75.7

MAX 18.5 19.5 21.6 24.7 27.8 30.9 34.6 40.2 43.3 49.4 61.8 68.0 80.3

28.3 31.2 38.5 50.3 63.6 78.5 98.5 133 154 201 314 380 531

6.6 6.9 7.7 8.8 9.9

8.1 8.5 9.5

CG5060 CG5063 CG5070 CG5080 CG5090 CG5100 CG5112 CG5130 CG5140 CG5160 CG5200 CG5220 CG5260

0.80 0.88 1.09 1.43 1.80 2.23 2.79 3.77 4.36 5.71 8.92 10.8 15.1

10.8 12.2 13.5 15.1 17.6 18.9 21.6 27.0 29.7 35.1

10.4 11.7 13.0 14.6 16.9 18.2 20.8 26.0 28.6 33.8

11.0 12.3 14.3 15.4 17.6 22.0 24.2 28.6

Sizes available up to 50.0mm • Factor of Safety 4:1

• Forces: BF = Breaking Force (min.)

P

dw

MPF = Manufacturing Proof Force (min.) WLL = Working Load Limit (F.O.S. = 4:1)(max)

A

• Mean stress at forces: BF = 500 MPa

MPF = 250 MPa WLL = 125 MPa • Calibration to P (max) available on request • Chain Heat Treatment: Hardened and Tempered • Chain Marking = MCK & 5 • Elongation = 20% (min.) • Chain sizes greater than 26mm with smooth weld only.

5

SectionA-A

A

DIMENSIONS (mm)

FORCES

APPROX MASS (kg/m)

PRODUCT CODE

PITCH (P)

DIAMETER (dn)

WLL (t)

G MAX 10.8 13.5 15.1 17.6

W2w MAX 29.6 37.0 41.4 48.1

dw MAX 8.8 11.0 12.3 14.3

MPF (kN) 31.7 49.5 63.0 84.0

BF (kN)

W2 MAX 29.2 36.5 40.9 47.5

W1 MIN

NOM 24.0 30.0 33.6 39.0

NOM 8.0 10.0 11.2 13.0

TOL ± 0.3 0.4 0.4 0.5

MIN 23.3 29.1 32.6 37.8

MAX 24.7 30.9 34.6 40.2

63.4 99.0 126 168

1.6 2.5 3.2 4.2

10.4 13.0 14.6 16.9

1.43 2.23 2.79 3.77

CG6080 CG6100 CG6112 CG6130

Factor of Safety 4:1

• Forces: BF = Breaking Force (min.)

MPF = Manufacturing Proof Force (min.) WLL = Working Load Limit (F.O.S. = 4:1)(max)

P

dw

A

• Mean stress at forces:

BF = 630 MPa MPF = 315 MPa WLL = 157.5 MPa

• Calibration to P (max) available on request • Heat Treatment: Hardened and Tempered • Chain Marking = Super-6 & MCK • Elongation = 20% (min.) • Conforms to the mechanical properties of ISO 3075: 1980.