Shutterlock Main Catalogue

LONG & EXTRA LONG LINK CHAIN GRADE 300

TO SANS 251 GRADE 3 LONG LINK CHAIN

DIMENSIONS (mm)

FORCES

APPROX MASS (kg/m)

PRODUCT CODE

PITCH (P)

DIAMETER MIN

WLL (t) 0.30 0.38 0.48 0.62 0.78 1.00 1.20 1.60 1.90 2.50 3.80 6.50

G MAX

dw MAX

MPF (kN)

BF (kN)

W2 MAX 19.6 22.1 24.9 28.0 31.5 35.0 39.2 45.5 49.0 56.0 70.0 91.0

W1 MIN 7.3 8.2 9.2

NOM

(dn) NOM

MAX

MIN

MAX

22.4 25.2 28.4 32.0 36.0 40.0 44.8 52.0 56.0 64.0 80.0 104.0

14.8 18.7 23.8 30.2 38.2 47.1 59.1 79.6 92.4 121 189 319

6.7 7.5 8.5 9.6

7.5 8.5 9.5

CLL056* CLL063 CLLO71 CLL080 CLL090 CLL100 CLL112 CLL130 CLL140 CLL160 CLL200 CLL260*

21.2 24.2 27.3 30.8 34.6 38.4 43.0 50.0 53.8 61.5 76.8 99.9

5.9 7.5 9.5

0.62 0.78 0.99 1.25 1.59 1.96 2.46 3.30 3.84 5.01 7.83 13.23

5.6 6.3 7.1 8.0 9.0

23.3 26.2 29.5 33.2 37.4 41.6 46.5 54.8 58.2 66.5 83.2 108.1

5.38 6.05 6.82 7.68 8.64 9.60

5.82 6.55 7.38 8.32 9.36

10.8 12.1 13.5 15.1 17.5 19.0 21.6 27.0 N/A

10.4 11.7 13.0 14.6 16.9 18.2 20.8 26.0 33.8

12.1 15.3 18.9 23.6 31.9 36.9 48.3 75.4 127

10.8 12.0 13.4 15.6 16.8 19.2 24.0 31.2

10.0 11.2 13.0 14.0 16.0 20.0 26.0

10.40 11.65 13.52 14.56 16.64 21.00 27.30

10.75 12.48 13.44 15.36 19.00 24.70

Sizes available up to 50.0mm • Factor of Safety 5:1

P

• Forces: BF = Breaking Force (min.)

dw

A

MPF = Manufacturing Proof Force (min.) WLL = Working Load Limit (F.O.S. = 5:1)(max)

• Mean stress at forces: BF = 300 MPa

MPF = 120 MPa WLL = 60 MPa

• Elongation 17% (min) • * Sizes not included or according to SANS 251 • Calibration to P (max) available on request. • All chain will be supplied with smooth weld only.

A

SECTION A-A

GRADE 3 EXTRA LONG LINK CHAIN

DIMENSIONS (mm) PITCH (P)

FORCES

APPROX MASS (kg/m)

PRODUCT CODE

DIAMETER MIN

WLL (t) 0.15 0.22 0.30 0.48 1.00 1.90 2.50

MPF (kN)

BF (kN) 7.5

dw MAX

W2 MAX 16.0 19.2 22.4 28.4 42.0 56.0 64.0

W1 MIN 6.8 8.2 9.5

NOM

(dn) NOM

MAX

MIN

MAX

20.0 24.0 28.0 42.6 60.0 84.0 96.0

3.0 4.3 5.9 9.5

0.30 0.43 0.59 0.89 1.77 3.47 4.53

4.8 5.7 6.7 8.5

CEL040 CEL048 CEL056 CEL071 CEL100 CEL140 CEL160

19.2 23.0 26.9 40.9 57.6 80.7 92.2

4.0 4.8 5.6 7.1

20.8 24.9 29.1 44.3 62.4 87.3 99.8

3.84 4.61 5.38 6.82 9.60

4.16 4.99 5.82 7.38

10.9 14.8 23.8 47.1 92.4 121.0

12.1 20.5 23.8 27.2

18.9 36.9 48.3

12.0 16.8 19.2

10.0 14.0 16.0

10.40 14.56 16.64

13.44 15.36

Factor of Safety 5:1

P

dw

A

• Forces: BF = Breaking Force (min.)

MPF = Manufacturing Proof Force (min.) WLL = Working Load Limit (F.O.S. = 5:1)(max)

• Mean stress at forces: BF = 300 MPa

MPF = 120 MPa WLL = 60 MPa

• Elongation 17% • Calibration to P (max) available on request.

A

SECTION A-A

LIFTING SALES DEPARTMENT

+2711 030 0400 | sales@shutterlock.co.za

Made with FlippingBook - Online magazine maker