Using electrical equipment in bathrooms or wet rooms requires attention to safety. The IEE Wiring Regulations (18th Edition) have identified particular zones within the bathroom to indicate what type of electrical equipment can be installed.

Zone 1 Up to 2250mm above bath, shower or wet room basin. A minimum rating of IP44. For 240V fittings, a 30ma RCD must also be used to protect the circuit.

Outside Zones Anywhere outside zones 0, 1 and 2, where water

Zone 2 600mm outside a bath, shower, sink or water outlet. A rating of at least IP44 is required.

Zone 0 Inside the bath, shower or wet room zone. This area requires a minimum rating of IP67 and must be low voltage (12V max).

jets are not used for cleaning purposes, the general rules of BS7671 apply.

DUST PROTECTION

0 No protection

1 Protected against a

2 Protected against solid objects over 12mm (eg. fingers)

3 Protected against solid ob- jects over 2.5mm (eg. tools)

4 Protected against solid ob- jects over 1mm (eg. wire)

5 Limited ingress of dust permitted

6 Completely protected

Bathroom zones & IP ratings The most important factor when choosing bathroom lighting is to ensure that the light fitting is suitable for use in the area it will be installed. Follow the product IP rating and bathroom zone guide to select the right level of protection. The higher the rating, the greater the protection against particles and water ingress.

solid object greater than 50mm (eg. a hand)

against ingress of dust

with no harmful deposit

WATER PROTECTION

0 No protection

1 Protected against ver- tical falling drops of water (eg. condensa- tion)

2 Protected against wa- ter drops at a 15 degree angle from the vertical

3 Protected against

4 Protected against sprays from any angle (eg. splashes of water)

5 Protected against light

6 Protected against powerful water jets

7 Protected against water immersion (up to 30mins

8 Protected against long periods of water immersion under pressure

sprays up to 60 degrees from the vertical

water jets from any direction

between 15cm and 1m)