AtkoreMasterElectricalProductsCatalog

General Fittings

Design Bolt Torque:

Dimensions: Imperial dimensions are illustrated in inches. Metric dimensions are shown in parenthesis or as noted. Unless noted, all metric dimensions are in millimeters and rounded to one decimal place. Design Load: Design load data, where shown, is based on the ultimate strength of the connection with a safety factor of 2.5, unless otherwise noted. Beam Clamps: Clamps are designed to be used with W, M, S and HP Shape beams, Standard C and Miscellaneous MC Channels, Angles and Structural Tees. Clamps must be used in pairs mounted in opposite directions where indicated. For beam clamps with HG finish, standard hardware is EG finish. For optional stainless steel hardware, please contact the factory for availability.

Bolt Size

Rec. Torque

Max. Torque

(ft/lb)

(N•m)

(ft/lb)

(N•m)

1⁄4 "-20 5⁄16 "-18 3⁄8 "-16 1⁄2 "-13 5⁄8 "-11 3⁄4 "-10

6

8

7

9

11 19 50

15 26 68

15 25 70

20 34 95

100 125

136 170

125 135

170 183

Set Screw Torque:

Bolt Size

Set Screw Torque

(in/lb)

(N•m)

1⁄4 "-20 3⁄8 "-16 1⁄2 "-13 5⁄8 "-11 3⁄4 "-10 7/8"- 9

40 60

4 7

125 250 400 665

14 28

44.5

75

Note: Caution should be taken not to overtighten the set screw

Made with FlippingBook - professional solution for displaying marketing and sales documents online