AtkoreMasterElectricalProductsCatalog

Fiberglass Cable Tray & Channel

Typical Properties

Typical Value Test Method

Typical Value

Unit

Polyester

Vinyl Ester

Direction

Electrical

Perpendicular

Volts/miI.

200

200

Electric Strength Short Time-in oil

ASTM D-149

Parallel

KV/in.

35

35

Dielectric Constant Dissipation Factor

ASTM D-150 ASTM D-150

Perpendicular Perpendicular Longitudinal or

F/M

5.0

5.0

0.03

0.03 120 120

Seconds Seconds

80 80

Arc Resistance

ASTM D-495

Transverse

Other Thermal Coefficient of Expansion

ASTM D-696

Longitudinal

in./in./°F

5" x 10-6

5" x 10-6

Thermal Conductivity

Longitudinal Longitudinal Longitudinal

BTU/Hr. sq. ft./in./°F

4 1

4 1

Water Absorption 24 hours

ASTM 0-570 ASTM D-792

%

Density

Ibs./cu.in.

0.062

0.062 Beige

Color (Standard)

Dark Gray

Flammability Flammability

UL94

Classification:

V-O

V-O

ASTME84 25 The foregoing list of properties was derived from laboratory data using coupon test specimens cut from pultruded sections. Such information should only be used as a general guide in design. Many actual components (such as cable tray side rail) take advantage of the flexibility of the pultrusion process and are selectively reinforced to enhance performance in a particular load axis. The factory should be contacted for specific information on any given component. Rating: 25