BlueCool S-Series Self-contained units
Technical data
BlueCool S-Series 230 V
Type
S6
S8
S10
S13
S16
S20
S27
Part numbers
WBCL120000
WBCL120001
WBCL120002
WBCL120003
WBCL120004
WBCL120005
WBCL120006
Cooling capacity* (BTU / h) Cooling capacity* (kW)
6,000
8,000
10,000
13,000
16,000
20,000
27,000
1.8 yes
2.4 yes
2.9 yes
3.8 yes
4.7 yes
5.9 yes
7.9 yes
Heating via reverse cycle integrated
Voltage (V)
230 (-15% / +10%) 230 (-15% / +10%) 230 (-15% / +10%) 230 (-15% / +10%) 230 (-15% / +10%) 230 (-15% / +10%) 230 (-15% / +10%)
Frequency (Hz)
50 / 60 (+-5%)
50 / 60 (+-5%)
50 / 60 (+-5%)
50 / 60 (+-5%)
50 / 60 (+-5%)
50 / 60 (+-5%)
50 / 60 (+-5%)
Current draw running** (A) 50 Hz Current draw max. peak (A) 50 Hz Current draw RMS40**** (A) 50 Hz Current draw RMS300*** (A) 50 Hz Current draw max. peak with Soft Start (A) 50 Hz Current draw RMS40**** with Soft Start (A) 50 Hz Current draw RMS300*** with Soft Start (A) 50 Hz Locked Rotor Amperage LRA (A)
2 – 2,4
2.4 – 3.5
2.6 – 4.0
3.6 – 6.3
4.9 – 7.1
5.9 – 8.9
7.0 – 10.5
14
28 17
27 17
37 22 11 13
54 35 19 22
60 39 20 23
77 49 32 34
5 3
9
9
11
12
11
4
7
7
7
12
14
19
3
5
5
5
9
10
17
12 16
19 16
19 16
24 16
37 16
43 16
62
Max. circuit breaker (A)
20 (comp. only)
Air flow (free blowing) (m³/ h) Air flow (free blowing) (cfm) Seawater connection (mm) Seawater connection (inch)
275 162 19 3/4
275 162 19 3/4
400 235 19 3/4
500 294 19 3/4
625 368 19 3/4
625 368 19 3/4
2 x 550 2 x 324
19 3/4
Min. seawater flow at 50 Hz (l / min.) Min. seawater flow at 60 Hz (l / min.) Recommended seawater pump +
6
8
10 12
12 14
14 17
17 20
21 25
7,5
10
WB250
WB350
WB350
WB350 / WB500G
WB500 / WB500G
WB500 / WB500G
WB1000 / WB1000G
Dimensions L x W x H (mm) Dimensions L x W x H (inch) Blower connection (mm) Blower connection (inch)
4 05 x 320 x 305 15.9 x 12.6 x 12.0
510 x 350 x 325 20.1 x 13.8 x 12.8
550 x 350 x 370 21.7 x 13.8 x 14.6
595 x 340 x 370 23.4 x 13.4 x 14.6
575 x 515 x 410 22.6 x 20.3 x 16.1
405 x 320 x 305 15.9 x 12.6 x 12.0
480 x 335 x 315 18.9 x 13.2 x 12.4
100 4
100 4
100 4
125 5
125 5
125 5
2 x 125 2 x 5
Weight (kg)
20
20
22
27
31
34
46
General note: Values in this table given for 50 Hz only. 60 Hz data available on request. * BTU / h are based on 7 °C evaporating temperature and 38 °C condensing temperature ** Amperage values for core unit depend on compressor load. Max values at tropical conditions at 230 V / 50 Hz *** Starting amperage RMS (Root Mean Square) for core unit for first 300 ms **** Starting amperage RMS (Root Mean Square) for core unit for first 40 ms + Recommendation only. Pump size shall be adapted to application constraints in order to always ensure minimal sea water flow.
Soft start device available as an option
BlueCool Expert, Display and Temperature Sensor access from outside
130
Made with FlippingBook Online newsletter