MRN_909559_2024-25_Catalog

Hot air system Air flow resistance calculation

To ensure correct application with the correct air distribution system, it is important to have a continuous main line with openings that cannot be closed. The sum of the resistance points of the main line must not exceed the maximum number of resistance points for each air heater model. Lines branching off from the main line are not taken into account. Consequently, the branches can also be designed with closable outlets. In the following table, several air ducting parts are listed. Exceeding the number of points (excessive air resistance of the heating air system) is detected by the heater after starting. For safety reasons, continuous heating operation is then no longer possible and the heater switches to control pause.

Air Top 2000 STC: max. 325 resistance points

Air Top Evo 40: max. 550 resistance points Air Top Evo 55: max. 375 resistance points

55 / 60 mm inlet

80 / 90 mm inlet

Dim. in mm

Points

Dim. in mm

Points

Id.

Id.

Intake grill / grille

60

24

1320163

90

65

1310581

Flexible tubing per meter

55

30

various

80

27

various

60

27

various

90

25

various

Additional points for elbow in flexible tube

55

10

various

80

7

various

60

8

various

90

6

various

Air ducting silencer

90

24

1321734

90

16

1320996

Reducing adapter air intake

90 > 80

45

1320186

Reducing adapter

60 > 55

27

1320127

80 > 55

223

1319477

90 > 60

211

1320760

90 > 80

45

1320185

90 > 80

45

1320925

Hose connector

55

12

1319473

80

5

1319476

60

10

1320469

90

5

1319869

51

Made with FlippingBook Online newsletter