ERS/ERG Series 4 CH 1400W Energy Recycling DC Power Supply 4 CH 5000W Energy Recycling Grid Type Power Inverter
Front Panel
Front Panel
ERS-1400 450x213x635 mm
ERG-5000 504x211x83.5 mm
Back Panel
Back Panel
Spec
■ ERS Features
■ ERG Features
·DC/AC Grid-connected Energy Recovery Inverter ·Wide input voltage range: 10~60VDC/60~420VDC by models ·Modular design, flexible configuration of aging tests in groups or partitions ·Flexible CC/CV operation modes ·Built-in CANBus communication interface, and can be used with CMU2A for remote monitoring, setting, data analysis and management ·Max. of 64 units ERG-5000 can be connected ·Protections: Over & Undervoltage/Over Temp./ Over Power/Grid Fault/Communication Error ·Aging test system, energy saving & carbon reduction ·5 years warranty
·AC/DC Energy Recovery System Power Supply ·Wide input voltage range: 10~60VDC/60~380VDC by models ·Modular design, flexible configuration of aging tests in groups or partitions ·Flexible CC/CV/CP operation modes ·Built-in CANBus communication interface, and can be used with CMU2A for remote monitoring, setting, data analysis and management ·Max. of 64 units ERS-1400 can be connected ·Protections: Over Voltage/Undervoltage/ Over Temp./Communication Error ·Aging test system, energy saving & carbon reduction ·5 years warranty
■ Models DC Input Voltage AC Input Voltage Vout / Iout Model No.
ERS-1400
ERS-1400H
ERG-5000
ERG-5000H
10~60VDC
60~380VDC
10~60VDC
60~420VDC
180~264VAC
N.A
320VDC, 0~6.3A
320VDC, 0~6.3A
180~264VAC, Single Phase ,24A
■ Application Diagram:
ERS-1400(H)
ERG-5000(H)
AC Input
Ethernet
Power Supply (up to 4 EUTs max.) ERG-5000 series
AC Utility
Power Supply (1~4EUTs)
ERS-1400 series
CMU2A
CMU2A
CMU2A System
Parm. Status Log Set Info ! Home
CC
Standby
Status
0 TOUCH TO STOP
A 0.5
STEP1
OTP
FAN
CANBus Interface or
CANBus Interface or
(320 Vdc)
Power Input
Communication Interface
Energy Recycle
Power Input (Energy Recycle)
Communication Interface
AC Input
71