Prodigi ™ Classic 6-10 (E/G)
Standard Power
6-10E
V Ph Hz AWG (IEC)
A Breaker
kW Connection
208–240V
208 3 50/60 240 3 50/60
8 8
21.9
40 40 32 32
7.9
3Ø/PE 3Ø/PE
25.3
10.5
6-10E ELECTRIC
380–415V
3
380
50/60
(4) (4)
20
9.0
3Ø/N/PE 3Ø/N/PE
415 3 50/60
22
10.5
440–480V
440 3 50/60 480 3 50/60
10 10
11.6
15 15
9.1
3Ø/PE 3Ø/PE
12.6
10.5
• Electrical connections must meet all applicable federal, state, and local codes. • For use on individual branch circuit only. • Ovens are not supplied with an electrical cord or plug. • For CE models use a Type B current protection device that accommodates a leakage current of 30mA.
Standard Power 6-10G V Ph Hz AWG (IEC) A Breaker kW Connection † 120V 120 1 60 12 6.8 20 0.84 1Ø/PE † 208 – 240V 208 3 50/60 14 4.8 15 1.0 3Ø/PE
240 3 50/60
14
4.2
15
1.0
3Ø/PE
380 – 415V380350/60 (0.75)
4.6
16
1.0
3Ø/PE
415350/60 (0.75)
4.2
16
1.0
3Ø/PE
6-10G ELECTRIC
† Per UL requirements, must be permanently connected to electrical supply source • Electrical connections must meet all applicable federal, state, and local codes. • For use on individual branch circuit only. • Ovens are not supplied with an electrical cord or plug. • For CE models use a Type B current protection device that accommodates a leakage current of 30mA.
Made with FlippingBook Publishing Software