Alto Shaam_Prodigi_6-10E PRO

Prodigi ™ Classic 6-10 (E/G)

Top: Left:

20” (508mm)

• Oven must be installed level. • Oven must be installed on noncombustible surface. • Water supply shut-off valve and back-flow preventer when required by local code. • Hood installation is required. • Drain must not be located directly underneath the appliance.

0” (0mm) 18” (457mm) recommended service access 0” (0mm) Non-combustible surfaces 2” (51mm) combustible surfaces

Right:

CHECK FIRST

CLEARANCE

Bottom: 5-1/8” (130mm) Back: 4” (102mm)

4-5/16” (109mm) optional plumbing kit

Noise emissions Without hood system, a maximum 67 dBA was measured at 3.3 ft (1 m) from unit. With hood system, a maximum 81 dBA was measured at 3.3 ft (1 m) from unit.

Heat of rejection 6-10E

BTU/hr

kW

630

0.18

HEAT: ELECTRIC

NOISE: ELECTRIC

Noise emissions NA

Heat of rejection

6-10G BTU/hr

kW

269

0.08

HEAT: GAS

NOISE: GAS

UL Marked Appliances

Maximum Input BTU/h

Minimum Input BTU/h

Maximum Inlet Pressure Inches WC (kPa)

Minimum Inlet Pressure Inches WC (kPa)

Maximum Fuel Consumption* CFH GPH

Natural Gas

43,000

32,000

14.0 (3.5) 14.0 (3.5)

5.5 (1.1)

45.7

N/A

GAS

Propane 0.5 *Assumes an average heating value for natural gs to be 1050 BTU/SCF and a specific gravity of 0.60. The assumed value for propane gas is 2,500 BTU/SCF, and a specific gravity of 1.53. 43,000 32,000 9.0 (2.8) 19.2

Gas Requirements (gas type must be specified on order) Hook-up: 3/4" NPT

Water requirements (per oven) • Two cold water inlets - drinking quality

Water Quality Standards It is the sole responsibility of the owner/operator/purchaser of this equipment to verify that the incoming water supply is comprehensively tested and, if required, a means of “water treatment” provided that would meet compliance requirements with the published water quality standards shown below. Non- compliance with these minimum standards will potentially damage this equipment and/or components and void the original equipment manufacturer’s warranty. Alto-Shaam recommends using the Alto- Shaam Reverse Osmosis System to properly treat your water.

• One treated water inlet: 3/4” NPT connection. Line pressure 30 psi minimum dynamic and 90 psi maximum static (200– 1000 kPa) at a minimum flow rate of 0.26 gpm (1 L/min). • One untreated water inlet: 3/4” NPT connection. Line pressure 30 psi minimum dynamic and 90 psi maximum static (200–1000 kPa) at a minimum flow rate of 2.64 gpm (10 L/min). Water drain: 1-1/2” (40mm) connection with a vertical vent to extend above the exhaust vent. Materials must withstand temperatures up to 200°F (93°C).

WATER

Inlet Water Requirements

Contaminant Treated Water

Untreated Water

Clearance requirements for water filtration system Do not install a water filtration system behind unit.

Free Chlorine

Less than 0.1 ppm (mg/L)

Less than 0.1 ppm (mg/L)

Hardness

30-70 ppm

30-70 ppm

Chloride

Less than 30 ppm (mg/L)

Less than 30 ppm (mg/L)

pH

7.0 to 8.5

7.0 to 8.5

CLEARANCE

Silica

Less than 12 ppm (mg/L)

Less than 12 ppm (mg/L)

Total Dissolved Solids (tds)

50-125 ppm

50-360 ppm