Amphenol Socapex │ PCB CONNECTORS │ R-VPX
INSTALLATION
The RVPX connector is design for simple installation. A Mechanical electric press or Arbor Press is used to compress the compliants into the plated thru holes seating the connector. Care should be taken to ensure even distribution of force across the housings. This can easily be achieved with the use of flat rock tooling. When pressing the module assemblies the connector over hangs the module board slightly. Because of this overhang a support plate is needed to ensure the connector gets fully seat- ed without bowing of the PCB. Extraction tools are available and suggested for backplane connector removal. Visual aid The illustration below shows a typical application of RVPX connectors. This illustration should be used by production personnel to ensure a correctly applied product.
Mounted connectors
MODULE ASSEMBLIES MUST BE FULLY SEATED TO DAUGHTERCARD
GUIDE MODULE MOUNTING SCREW MUST BE SECURE
P1
P0
P6
P2
P5
P4
P3
ORIENTATION OF GUIDE PIN KEY MUST MATCH GUIDE MODULE KEY
J6
J5
J4
J3
J2
J1
J0
MODULE MUST BE FULLY SEATED TO BACKPLANE
MODULE KEYS MUST BE FULLY SEATED IN ADJACENT MODULES
GUIDE PIN MUST BE FULLY SEATED AND HARDWARE SECURED
Mated connectors
ALL MODULES AND GUIDE ASSEMBLIES MUST BE FULLY MATED
P1
P0
P2
P6
P5
P4
P3
All dimensions are given for information only and are in inch, except as otherwise specified │ *in mm: 1mm=0.03937 inch
Amphenol SOCAPEX
Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex