Catalog PCB Connectors

Amphenol Socapex │ PCB CONNECTORS │ 127/HE8

GENERAL CHARACTERISTICS - 127/HE8

STANDARD / APPROVALS • NFC UTE 93424

CONNECTOR TYPES • HE801: cylindrical pin • HE804: rectangular pin • HE807 / 127H : hybrid version • F = Female contact • M = Male contact

TYPE OF CONTACTS • Low level signal contacts: 3A • Power contacts: 10A & 20A • Coaxial contacts

- HE801 - HE804 - HE807

• BS9525

- N0001 - F0006 - F0007 • MIL DTL 55302

- /140 to /155

NUMBER OF ROWS • 2 rows • 3 rows

ARRANGEMENTS • From 17 to 144 low level signal contacts • From 0 to 10 special contacts: power or coaxial

CONTACT DENSITY • Medium density: 2.54 [.100] staggered grid (1.27 [.050] offset), 2.54 [.100] between rows

MATERIALS Female contact • CuSn9P, stamped and formed Male contact • CuZn, stamped and formed Guiding devices • Electroless nickel over brass or Passivated stainless steel 303 Plastic insert • Thermoset DAP, 30% glass-fiber filled

FEMALE CONTACT • Turning fork contact • Selective plating • Advanced copper alloys

PLATING Contact terminations • Tin lead or lead free on YD, Y, Z, ZC, YC, contacts • Gold on X, X1 contacts

• Optimized electrical conductivity • Long-term mechanical reliability • Selective plating

Active contact area • Gold over Nickel

[0.024] 0,6

MALE CONTACT Mating end diameter

H

• HE801 & HE807: cylindrical section Ø 0.6[.024] • HE804: rectangular section: 0,8x0,6 [.031 x .024]

0,8 [0.031]

[0.024] 0,6

Technical specifications Mechanical characteristics 0,8 [0.031]

127/HE8

A

Plan originel ECHELLE

DESSIN: le

Backoff 1 (mm)

Amphenol Socapex

1

MAX [.039]

2,000

TECHNIQUE:

BP 29 - 74311 THYEZ CEDEX

1/1

Mating force per contact (N)

1,60 MAX 0,14 MIN

Unmating force per contact (N)

Durability cycles

500

Vibrations (10 to 2000 Hz) micro discontinuity 1ns

10 g

Shocks micro discontinuity 1µs A Plan originel ECHELLE

100 g

DESSIN: le

Amphenol Socapex

2,000

TECHNIQUE:

Recommended tightening torques Nuts for Ø 2,5mm screws, brass (m.N) Nuts for Ø 1,6mm screws, brass (m.N) Environmental characteristics Thermal shocks (°C) BP 29 - 74311 THYEZ CEDEX

1/1

0,25 0,15

Derating Curve

0 0.5 1 1.5 2 2.5 3.5 3

-55 / + 125

Salt Spray (hours)

96

Electrical characteristics Current rating per contacts (A)

3 (see derating curve)

Insulation resistance (GΩ)

5 MIN

Contact resistance (mΩ)

12 MAX

Dielectric Withstanding Voltage (Vrms)

1000 MIN

Service Voltage (at 50Hz) (Vrms)

250

0

50

100

150

Temperature (°C)

All dimensions are given for information only and are in mm [inch], except as otherwise specified │ *in mm: 1mm=0.03937 inch 1 : When both connectors are fully mated, the backoff is the maximum distance the connectors can be unmated while functioning properly

Amphenol SOCAPEX

Due to technical progress, all information provided is subject to change without prior notice Designed by Amphenol Socapex

127

Made with FlippingBook HTML5