SANITATION & CLEAN ROOM SOLUTIONS / 17
Tank holds 600 gallons of fresh water to pump through system. CIP Skid Tank Add steam to the holding tank to increase to the desired temperature range. Steam Sparging Port (Back Side)
Easily take mixture samplings of solution. Sampling Port
Measures conductivity of solution which con- trols the dosing pump volume discharge. Conductivity Sensor
Mixes the fresh water and chemicals. Helical Static Meter
Measures level of water in tank and shuts off incoming water when activated. High Level Switch
Pumps cleaning and sanitation chemical into the line to be mixed with fresh water. Tacmina Metering Pumps
Measures water flow in the piping and displays on the oven controller. Electromagentic Flow Meter
Measures pressure (elevation of the water) in the tank and the piping and displays on the oven controller. Pressure Sensors
Holds cleaning and sanitation chemical containers while connected to pumps. Chemical Container Shelf
Measures temperature in the tank and the piping and displays on the oven controller. Can be used to activate steam sparging line to maintain desired temperature. Temperature Sensors
High powered pump moves water through the system and pushes it into the CIP system. Main Pump
Measures level of water in tank and shuts off system when not enough water is present. Low Level Switch
FTIINC.ORG/CLEAN