F100 Ethernet
Inductive Coupling System
■ Contact free transmission of energy and signals
Axial coupler
Application/customer benefits • Contact free transmission of energy and signals between moving / rotating and stationary components • Application examples: Robotic (END OF ARM TOOLING), Automation, Mechanical engineering • Substitution of slip ring / connector • Dynamic Pairing • Wear and maintenance free • Protective functions: temperature monitoring, foreign object detection, reverse polarity protection • Multi-level LED with good visibility Technical features • Diameter 100 mm / Through hole 50 mm
• Operating voltage 24 V / max 6 A • Transmission distance 0 - 4 mm • Transmission of energy 24 V / 75 W • Transmission of signals Ethernet 100 Base-T • Transmission bandwidth: < 5 MBit/s • Connections: M12 Ethernet (D-coded) / M12 Power (L-coded) • Protection class: IP 67
Standard equipment Inductive coupler base or remote
Block diagram
24 V / 75 W
Energy
24 V / 6 A
24 V / 4 A
Controller 24 V
Power electronic
Rectier
DAV /
Control
Control
Diagnosis
DAV / Diagnosis
PLC
Ethernet 100 BaseT
Ethernet 100 BaseT
Signal transmission
Signal transmission
Base
Remote
Signals
Subject to technical changes. For more detailed information please ask our customer service.
Ethernet
Inductive coupling system F100 Ethernet
Type Id. No.
Base
Remote
0E011420
0E011421
Operating temperature (housing surface) Storage temperature Transmission distance Operating voltage Output voltage Signal transmission Ethernet (bidirectional)
-20 °C ... +60 °C -20 °C ... +60 °C 0 mm ... 4 mm
24 V
-
-
24 V (75 W)
Ethernet 100 Base-T
LED
2 LEDs 2-color
Current consumption (Base) Overload protection / short circuit protection Residual ripple Reverse polarity protection Data-Valid output Ready delay
6 A (24 V)
-
-
< 50 mV
-
max. 100 mA < 1s