Digitized Workholding 2024

F100-2IOL

Inductive Coupling System

■ Contact free transmission of energy and signals

Axial coupler

Application/customer benefits • Contact free transmission of energy and signals between moving / rotating and stationary components • Application examples: Robotic (End of Arm Tooling), Automation, Mechanical engineering • Substitution of slip ring / connector • Dynamic Pairing • Wear and maintenance free • Protective functions: temperature monitoring, foreign object detection, reverse polarity protection • Status LED with good visibility Technical features • Diameter 100 mm / Through hole 50 mm • Operating voltage 24 V / max. 6 A • Transmission distance 0 - 4 mm • Transmission of energy 24 V / 75 W • Transmission of signals: 2 x IO-Link (COM 1, COM 2, COM 3) • Connections: Base: 2x M12 x 1 male 5-pin, Remote: 2x M12 x 1 female 5-pin • Protection class: IP67

Standard equipment Inductive coupler base or remote

Block diagram

24 V / 75 W

Energy

24 V / 2x 3 A

24 V / 4 A

Controller 24 V

Power electronic

Rectier

Control

Control

Diagnosis

DAV /

Diagnosis

IO-Link Master 1,2

2 x IO-Link

2 x IO-Link

Signal transmission

Signal transmission

Base

Remote

Signals

2x IO-Link COM1, COM2, COM3

Subject to technical changes. For more detailed information please ask our customer service.

Inductive coupling system F100-2IOL

Type Id. No.

Base

Remote

0E012330

0E012331

Operating temperature (housing surface) Storage temperature Transmission distance Operating voltage Output voltage Signal transmission

-20 °C ... +60 °C -20 °C ... +60 °C 0 mm ... 4 mm

24 V

-

-

24 V (75 W)

2x IO-Link (COM2, COM 2, COM 3)

LED

2 LEDs 2-color

Current consumption (Base) Overload protection / short circuit protection Residual ripple Reverse polarity protection Data-Valid output Ready delay

6 A (24 V)

-

-

< 50 mV

-

max. 100 mA < 1 s