F180 Ethernet
Inductive Coupling System
■ Stationary Unit - Base ■ Mobile Unit - Remote
Axial coupler
Base:
Base / Remote:
Base / Remote:
C
H
C
H
H 1
H 1
Remote:
Subject to technical changes. For more detailed information please ask our customer service.
Inductive coupling system F180 Ethernet
Base
Remote
Type Id. No.
0E011246
0E011247
A B
mm mm mm mm mm mm mm mm mm
180
85 93
B1
C D
29.5
57 20
E F
5
H
34
H1
7
ɑ
60 Al, GFK IP67
degree
Housing material Protection class
Function Base LED Power Color
Function Remote LED Actuator Color
Green / red
Green / red
Off » Unit not supplied with voltage (or undervoltage) On (green) » Voltage ok and mobile unit has been detected 2 Hz green 50/ 50% » Operating temperature in critical range 1 Hz green 25/75% » Voltage ok but no mobile unit detected 1 Hz red / green » Incompatible mobile unit detected 2 Hz red » Foreign element detected 5 Hz red » Internal error
Off » Unit not paired On (green) » Unit paired, voltage output actuator ok Flashes 2 Hz red » Unit paired but short circuit on actuator Flashes 5 Hz red » Internal error
Function
Function
LED Sensor supply Color
Green / red
Off » Unit not paired On (green) » Unit paired, voltage output sensor (24 V) ok Flashes 2 Hz red » Unit paired but short circuit on sensor (24 V) Flashes 5 Hz red » Internal error
LED Signal transmission Ethernet Color Yellow / red
Function
Off » No mobile unit detected On / yellow » Signal transmission ready 1 Hz yellow » Data packets are being transmitted 3 Hz yellow » 50% of the transmission bandwidth used (10 s) 8 Hz red » Data packets were discarded (in the last 10 s) On / red » Error in data transmission (internal error)
LED Signal transmission Color Yellow / red
Function
Off » No mobile unit detected On / yellow » Signal transmission ready
Flashes 1 Hz yellow » Data packets are being transmitted Flashes 3 Hz yellow » 50% of the transmission bandwidth used (10 s) Flashes 8 Hz red » Data packets were discarded (in the last 10 s) On / red » Error in data transmission (internal error)
LED Energy transmission Color Yellow / red
Function
Off » No mobile unit detected On (yellow) » Unit coupled, voltage output ok
1 Hz red / yellow » Short circuit at voltage output sensor 3 Hz red / yellow » Short circuit at voltage output actuator 3 Hz red » Short circuit at both voltage outputs 5 Hz red » Internal error
Function
SMW-AUTOBLOK 45
Made with FlippingBook Publishing Software