Digitized Workholding 2024

M18-4

Inductive Coupling System

■ Stationary Unit - Base ■ Mobile Unit - Remote

Axial coupler

Base:

24

D

C

B

Remote:

24

D

C

B

Subject to technical changes. For more detailed information please ask our customer service.

Inductive coupling system M18-4

Base

Remote

Type Id. No.

0E010954

0E010955

A B C D

mm mm mm mm mm

M18 x 1

98.5

65.5

70

37

10

Cable length Housing material Protection class Operating temperature

~ 2000 CuZn, PA66, PC GF 30% IP67 0° C ... +50° C -10° C ... +70° C 0 mm ... 3 mm

Storage temperature Transmission distance Operating voltage Output voltage Power consumption (Base) Power output (Remote) Overload protection / short circuit protection Residual ripple Reverse polarity protection Data-Valid Output Ready delay PIN assignment (*Legend) Connection line WH (Base) / WH (Remote) Connection line BU (Base) / BU (Remote) Connection line GY (Base) / BN (Remote) Connection line BN (Base) / PK (Remote) Connection line PK (Base) / YE (Remote) Connection line YE (Base) / GN (Remote) Connection line GN (Base) / GY (Remote)

22 V ... 30 V

-

-

12 V ± 10% DC

≤ 500 mA

-

-

< 100 mA

-

< 200 mV

- -

max. 100 mA

< 80 ms

PIN 1 2 3 4 5 6 7

Signal Base

Signal Remote

Supply voltage 24 V IN

Supply voltage VCC 12 V OUT

GND 0 V

GND

Data-Valid 0 / 24 V OUT

Digital signal 1: 0 / 24 V IN Digital signal 2: 0 / 24 V IN Digital signal 3: 0 / 24 V IN Digital signal 4: 0 / 24 V IN

Digital signal 1: 0 / 24 V OUT Digital signal 2: 0 / 24 V OUT Digital signal 3: 0 / 24 V OUT Digital signal 4: 0 / 24 V OUT

-

(*Legend) WH = White; BU = Blue; GY = Grey; BN = Brown; PK = PINK; YE = YELLOW; GN = Green;

SMW-AUTOBLOK 53

Made with FlippingBook Publishing Software