Digitized Workholding 2024

LPS 4.0 IO Linear Position Sensor System High-precision inductive linear position sensor

Standard connection M12 x 1 (5 Pole)

Common communication interfaces: ■ IO-Link ■ Analog signal: (0 -10 V/4 -20 mA)

Status displays LEDs Operation and Target detection

Inductive position measurement by target / encoder unit

Sensor

Housing plastic Protection class: IP67 / 69K

Operating distance

Target/ encoder unit

Required dimensions: LPS 4.0 48/80/120 IO TARGET / ENCODER UNIT DESIGN

Dimensions

Remark

A = Required distance (light and parallel) between measuring surface and the operating ring

Operating distance A = 1.0 mm ± 0.25

Width B = 19 mm

B = Required width of the operating cam or operating ring

Angle α = 6°

α = Angle min. 6°

Ring

Cam

α

A

B

B

α

Example:Target / encoder unit (cam geometry)

Example:Target / encoder unit (ring geometry)

Made with FlippingBook Publishing Software