M30-IOL
Inductive Coupling Sytem
■ Contact free transmission of energy and signals
Axial coupler
Application / customer benefits • Contact free, safe transmission of energy and signals between moving / rotating and stationary components • Application examples: Supply of sensors, supply and monitoring of remote systems • Dynamic Pairing • Wear and maintenance free • Protective function: Temperature monitoring, foreign object detection, reverse polarity protection • Multi-level LED with good visibility Technical features • Mounting: M30 x 1.5 • Operating voltage: 24 V ± 10 % • Transmission distance: 0 - 7 mm • Transmission of energy: 24 V / 12 W • Transmission of signals: IO-Link (COM1, COM2, COM3), 1 digital signal • Connection: Base male connector M12 x 1 (5-pin), remote female connector M12 x 1 (5-pin) • Protection class: IP67
Standard equiment Inductive coupler Base or Remote
Block diagram
IO-Link Master
24 V/12 W
Energy
IO-Link Device
0 - 7 mm
Base
Remote
Signals
IO-Link COM1, COM2, COM3
Subject to technical changes. For more detailed information please ask our customer service.
LED Function display Base LED Power Color Green
LED Function display Remote LED Coupling Color Green
Off green » Unit not supplied with voltage Flashes green for 3 s / 0.5 s » Device is supplied with voltage, remote coupler not detected On green » Voltage ok and remote coupler detected Flashes 2 Hz green » Alternately U in > 30 V, remote overload Flashes 2 Hz green » Base coupler overtemperature Flashes 2 Hz green » Foreign object detected
Off green » Device is not coupled On green » Device is coupled and 24 V out ok 2 Hz green » Overload at 24 V out or insufficient power supply 2 Hz green » Overtemperature
Function
Function
LED IO-Link Color
Yellow
Off yellow » No base coupler detected On yellow » Base coupler detected, no IOL mode Flashes 1 s/100 ms yellow » IOL mode (COM1, COM2, COM3)
Function
LED IO-Link Color
Yellow
LED Signal Color
Off yellow » No remote coupler detected On yellow » Remote coupler detected, no IOL mode Flashes 1 s/100 ms yellow » IOL mode (COM1, COM2, COM3)
Function
Yellow
Off yellow » Digital channel not switched (low) On yellow » Digital channel switched (high)
Function
LED Signal Color
Yellow
Off yellow » Digital channel not switched (low) On yellow » Digital channel switched (high) Flashes 2 Hz yellow » Digital output overload base coupler
Function
66 SMW-AUTOBLOK