Digitized Workholding EN

M30-IOL

Inductive Coupling Sytem

■ Contact free transmission of energy and signals

Axial coupler

Application / customer benefits • Contact free, safe transmission of energy and signals between moving / rotating and stationary components • Application examples: Supply of sensors, supply and monitoring of remote systems • Dynamic Pairing • Wear and maintenance free • Protective function: Temperature monitoring, foreign object detection, reverse polarity protection • Multi-level LED with good visibility Technical features • Mounting: M30 x 1.5 • Operating voltage: 24 V ± 10 % • Transmission distance: 0 - 7 mm • Transmission of energy: 24 V / 12 W • Transmission of signals: IO-Link (COM1, COM2, COM3), 1 digital signal • Connection: Base male connector M12 x 1 (5-pin), remote female connector M12 x 1 (5-pin) • Protection class: IP67

Standard equiment Inductive coupler Base or Remote

Block diagram

IO-Link Master

24 V/12 W

Energy

IO-Link Device

0 - 7 mm

Base

Remote

Signals

IO-Link COM1, COM2, COM3

Subject to technical changes. For more detailed information please ask our customer service.

LED Function display Base LED Power Color Green

LED Function display Remote LED Coupling Color Green

Off green » Unit not supplied with voltage Flashes green for 3 s / 0.5 s » Device is supplied with voltage, remote coupler not detected On green » Voltage ok and remote coupler detected Flashes 2 Hz green » Alternately U in > 30 V, remote overload Flashes 2 Hz green » Base coupler overtemperature Flashes 2 Hz green » Foreign object detected

Off green » Device is not coupled On green » Device is coupled and 24 V out ok 2 Hz green » Overload at 24 V out or insufficient power supply 2 Hz green » Overtemperature

Function

Function

LED IO-Link Color

Yellow

Off yellow » No base coupler detected On yellow » Base coupler detected, no IOL mode Flashes 1 s/100 ms yellow » IOL mode (COM1, COM2, COM3)

Function

LED IO-Link Color

Yellow

LED Signal Color

Off yellow » No remote coupler detected On yellow » Remote coupler detected, no IOL mode Flashes 1 s/100 ms yellow » IOL mode (COM1, COM2, COM3)

Function

Yellow

Off yellow » Digital channel not switched (low) On yellow » Digital channel switched (high)

Function

LED Signal Color

Yellow

Off yellow » Digital channel not switched (low) On yellow » Digital channel switched (high) Flashes 2 Hz yellow » Digital output overload base coupler

Function

66 SMW-AUTOBLOK

Made with FlippingBook Publishing Software