Clean Air America WeldStation Basic User Manual

R EMOVING THE I NTERNAL P ANEL B AFFLES

The internal spark baffles must be removed for some Weld Station installations. Internal baffles are located in both the main unit and secondary booth. 1. Begin by loosening and removing the bolts on both the left and the right side of the baffle plate. This should allow the baffle plate to fall free from the vertical supports. 2. Reach into the intake opening and slide the baffle midway to the opposite side of the booth in front of the vertical supports. 3. Rotate the baffle so that one side begins to twist into the back of the back of plenum area. 4. Tilt the baffle plate at a 45 degree angle to remove it through the front intake of the booth.

5. Repeat steps 1 through 4 with any other baffles.

Copyright © Clean Air America, Inc.

Weld Station User Manual, March 2011