I NSTALLING THE I NTERNAL P ANEL B AFFLES

The internal spark baffles must be installed before using the Weld Station. Internal baffles are located in both the main unit and secondary booth.

1. Begin by tilting the baffle at about a 45 degree angle

2. Slide the baffle into the intake plenum through the intake opening. Slide it in past the internal baffle support. 3. Once the baffle is entirely inside the plenum area, rotate the baffle so that it is vertical.

4. Then slide the baffle forward in front on the intake supports.

5. Once the baffle is vertical in front of the supports, place it flush on the supports and slide it up so that the bolt pattern on the baffle is aligned with the bolt pattern on the baffle supports. 6. Fasten the baffle to the supports inside the plenum area using (6) 1/4" - 20 x 0.75" zinc plated hex head bolts, (6) 1/4" zinc plated flat washers, and (6) 1/4" zinc plated lock washers.

7. Repeat steps 1 through 6 with any other baffles.