Clean Air America WeldStation Basic User Manual

I NSTALLING THE L EVER H ANDLES

For each main unit, there are two lever handles. These handles must be installed in the filter compartment door for increased ease of maintenance. Remove the bolts holding the filter door shut. The door was bolted shut during shipping to prevent damage to the lever handles. Make sure to keep the 3/8" flat washers; however, the 3/8" retaining bolts can be discarded.

The filter door may swing open allowing access to the filter compartment.

Swing the filter door closed.

Place a 3/8" zinc flat washer on each of the lever handles.

Place the threaded stud of the lever handles through the holes in the filter door arms.

Screw the lock nut onto the back of the lever handle. This will keep the lever handle attached to the door during maintenance and prevent the loss of hardware.

Screw the lever handle into the weld nut and tighten the door down.