How to replace filters
NOTE:
It is important to ensure that the filter gaskets seal correctly for proper operation of the Weld Station. This will ensure that you do not get particulate past the filter compartment. The easy filter clamping system of the Weld Station helps with faster filter replacement and maintenance.
1) Press the red 'STOP' button and allow blower to spin down. This may take several minutes. 2) Rotate the Disconnect Switch / Emergency Stop Switch to the '0' or 'OFF' position. This will disconnect power to the unit to prevent the unit from being started during the filter change. Please follow all lock out - tag out procedures.
3) Shut off the compressed air supply to the Weld Station.
4) Open the filter door by simply removing the lever handles handles. Make sure to retain the bearing washers so that the washers can be replaced when finished. 5) Swing the door open to allow access to the filter compartment and reveal the cartridge filters. 6) Release the first filter by loosening the filter clamp at the top of the filter. This is done by rotating the metal T-handle clockwise when viewed from below. As the clamp spins, it will release pressure from the filters. Make
Copyright © Clean Air America, Inc.
Weld Station User Manual, March 2011
Page 72 of 112