Clean Air America WeldStation Basic User Manual

sure to create a gap between the filter cap and the end of the clamp.

7) Once the clamp has been loosened, the filter can be accessed.

8) Remove and set aside the filter cap. Do not discard it.

9) Slide a large plastic bag over the top of the filter cartridge, and slide the bag over the filter to the bottom of the filter cartridge.

10) Remove the filter in the bag and tie the end of the bag closed.

11) Cover the filter duct and ring to avoid dirt or dust entering the clean air duct. Make sure to cover the entire duct and filter ring. A plastic bag can be used.

12) Repeat steps 6 through 11 for the remaining filters.

13) Clean each of the filter caps. This can be done by simply blowing them off with a compressed air nozzle or wiping them clean with a dry cloth. Make sure not to damage the gasket of the filter cap. 14) Some excess dust and debris may need to be removed while the filters have been removed from the unit. This can be done by sweeping the dust into the dust trays. The dust trays can then be serviced as normal. Alternatively, excess dust in the

Copyright © Clean Air America, Inc.

Weld Station User Manual, March 2011

Page 73 of 112

Made with FlippingBook Digital Publishing Software