the side of the bottom plenum, including bold holes. Take a grinder with a cutting wheel, and

cut just inside the outline you created. Lastly, drill out the holes for the bolts.

Now attach lifting chains to the bottom plenum, and move it to your desired location with a fork

lift. If a forklift is too large to fit in the area, moving dollies may be needed. Carefully set both

ends on a dolly and maneuver the bottom plenum into place.

Once you have the bottom plenum set in the area you wish to operate the unit, bring in the

filter columns one at a time and reinstall them onto it.

When remounting the filter columns, you must install the middle

column FIRST . It is also important to insert the bolts upright;

from the filter housing down, with the nuts being attached from

the bottom plenum. Do NOT tighten them yet. Make sure not to

damage the gasket.

After the middle column has been attached to the

bottom plenum, repeat the steps to attach the

remaining columns. Here you may find it difficult

to realign the filter housing bolt holes with the

bottom plenum bolt holes. This can be easily

fixed by inserting a large philips screwdriver into

the corner bolt holes, and prying them into

alignment. Once they are aligned, insert a bolt

into neighboring holes and repeat on each

corner. Once all the bolts have been replaced,

tighten them.