ELECTRICAL CONNECTION DIAGRAMS
Clean Air Industries ZeroMist units can be set up to operate on various power sources. Before mounting the electric panel in your desired location, look at the following electrical charts to determine power
required. Any damage incurred from improper electrical power connection will void the warranty of the
ZeroMist.
Connect the main power line into the top of the power disconnect. Then run wires from the motor(s) into
the outgoing side of the VFD. Lastly, run wires from the pressure sensor into the electric panel. (See
wiring diagrams for more information)
The incoming power is connected to the electrical panel.
First make the ground connection into the grounding terminal block.
The incoming power wires must be terminated on the incoming sides of the power disconnect
switch. (L1, L2, L3)
Primary branch circuit protection must be provided by the end user. The breaker must have J-
Class Fast Acting Fuses.