The Manual Speed Setting numerical display shows the speed at which the Variable Frequency Drive (VFD) inside the unit is set. The unit will not ramp up or down to this setting until the Set button is pressed. This prevents accidental repeated ramping up or down due to user error. To change the value, use the Increment Up and Increment Down buttons to change the setting by 1 Hz. By touching the Manual Speed Setting numerical display, a keypad will appear on the screen which can be used to enter the number directly.