Filter Alarm Pressure Setting - This option sets the pressure differential at which the filter alarm light is illuminated. This is typically used to signify when to change the filters.
This values is measured in inches of water column (in. H 2 O).
This pulsing state is referred to as the online cleaning cycle.
To change the value, use the 'Increment Up' and 'Increment Down' buttons to change the setting by 0.1 in. H 2 O. By touching the numerical display, a keypad will appear on the screen which can be used to enter the number directly.
Number of Cycles at Shut Down - This option sets the number of pulses performed during the shutdown sequence. In the Weld Station there are two pulsing valves. Each valve will be pulsed this many time alternating between the valves.
This pulsing state is referred to as the offline cleaning cycle.
To change the value, use the 'Increment Up' and 'Increment Down' buttons to change the setting by 1. By touching the numerical display, a keypad will appear on the screen which can be used to enter the number directly.