S TARTUP P ROCEDURES

The Dual WeldStation power must first be turned on by rotating the Power Disconnect / Emergency Shut Off switch to the 'ON' position.

The unit can then be started by simply depressing the green "RUN" button.

The blower will start immediately, but may take a minute or two to reach full speed.

The automatic pulse cleaning system will automatically turn on in the automatic mode.

S HUTDOWN PROCEDURES

Proper Dual WeldStation shutdown is one of the key factors to achieving maximum filter cartridge life. To properly shutdown the Dual WeldStation LEAF TM , simply turn the three way mode switch to '0'. After approximately 1 minute, the Dual WeldStation will begin to cycle through its offline cleaning process. If the default settings are being used, this will take about 3 to 4 minutes. However, if the default settings are not being used, this off line cleaning cycle could take upwards of 10 minutes. Always wait for the cleaning process to finish before disengaging the Power Disconnect / Emergency Shut Off switch. The Dual WeldStation can be shutdown easily by turning the mode switch to '0'.

The blower will not stop immediately, and may take several minutes to fully stop.

The automatic cleaning system will continue to operate once the mode switch is changed AND the blower has stopped. This is normal and desirable; the off line cleaning is the most efficient cleaning method.

Do NOT use the Power Disconnect / Emergency Shut Off switch to deactivate the unit unless it is an emergency situation.

NOTE:

Do NOT shut down the Dual WeldStation by disengaging the Power Disconnect / Emergency Shut Off unless it is an emergency situation. If the Dual WeldStation is shut down in this manner, it will NOT perform offline cleaning and will diminish the life of the filter cartridges.