R EMOVING THE I NTERNAL P ANEL
B AFFLES
The internal spark baffles must be removed for
some WeldStation installations. Internal baffles
are located in both the main unit and secondary
booth.
1. Begin by loosening and removing the
bolts on both the left and the right side of
the baffle plate. This should allow the
baffle plate to fall free from the vertical
supports.
2. Reach into the intake opening and slide
the baffle midway to the opposite side of
the booth in front of the vertical supports.
3. Rotate the baffle so that one side begins
to twist into the back of the back of
plenum area.
4. Tilt the baffle plate at a 45 degree angle
to remove it through the front intake of the
booth.
5. Repeat steps 1 through 4 with any other
baffles.