Clean Air Industries WeldStation EVO User Manual

I NSTALLING THE I NTERNAL P ANEL

B AFFLES

The internal spark baffles must be installed before

using the WeldStation. Internal baffles are located

in both the main unit and secondary booth.

1. Begin by tilting the baffle at about a 45

degree angle

2. Slide the baffle into the intake plenum

through the intake opening. Slide it in past

the internal baffle support.

3. Once the baffle is entirely inside the

plenum area, rotate the baffle so that it is

vertical.

4. Then slide the baffle forward in front on

the intake supports.

5. Once the baffle is vertical in front of the

supports, place it flush on the supports

and slide it up so that the bolt pattern on

the baffle is aligned with the bolt pattern

on the baffle supports.

6. Fasten the baffle to the supports inside

the plenum area using (6) 1/4" - 20 x

0.75" zinc plated hex head bolts, (6) 1/4"

zinc plated flat washers, and (6) 1/4" zinc

plated lock washers.

7. Repeat steps 1 through 6 with any other

baffles.

Page 32 of 83

1-866-665-1829

clean-air.com

sales@clean-air.com

Made with FlippingBook - professional solution for displaying marketing and sales documents online