I NSTALLING THE I NTAKE S PARK B AFFLES
All of the intake spark baffles must be installed
before using the WeldStation. These baffles are
the first defense in stopping sparks from passing
into the WeldStation. Smaller width secondary
booths will only have one spark baffle of each
type. The metal mesh spark baffles must be installed behind the Reverse Flow TM spark baffles.
1. First, carefully slide the top of the metal
mesh spark baffle upward into the top
channel of the intake at a slight angle
(approximately 10 degrees).
2. Then push the bottom of the metal mesh
spark baffle inward so that the baffle is
vertical and aligned with the bottom
channel of the intake.
3. Next slide the metal mesh spark baffle
down into the bottom channel of the
intake.
4. Slide the metal mesh filter all the way to
the right hand side of the intake. Make
sure it is seated in the bottom of the
channel and shifted so that it is flush with
the side of the intake.
5. Repeat steps 1 through 4 for the other
metal mesh spark baffle; however slide
the second baffle all the way to the left.
6. Repeat steps 1 through 4 for the (2) Reverse Flow TM spark baffles; placing first
on the right and the second on the left.