Clean Air Industries WeldStation EVO User Manual

I NSTALLING THE I NTAKE S PARK B AFFLES

All of the intake spark baffles must be installed

before using the WeldStation. These baffles are

the first defense in stopping sparks from passing

into the WeldStation. Smaller width secondary

booths will only have one spark baffle of each

type. The metal mesh spark baffles must be installed behind the Reverse Flow TM spark baffles.

1. First, carefully slide the top of the metal

mesh spark baffle upward into the top

channel of the intake at a slight angle

(approximately 10 degrees).

2. Then push the bottom of the metal mesh

spark baffle inward so that the baffle is

vertical and aligned with the bottom

channel of the intake.

3. Next slide the metal mesh spark baffle

down into the bottom channel of the

intake.

4. Slide the metal mesh filter all the way to

the right hand side of the intake. Make

sure it is seated in the bottom of the

channel and shifted so that it is flush with

the side of the intake.

5. Repeat steps 1 through 4 for the other

metal mesh spark baffle; however slide

the second baffle all the way to the left.

6. Repeat steps 1 through 4 for the (2) Reverse Flow TM spark baffles; placing first

on the right and the second on the left.

Page 33 of 83

1-866-665-1829

clean-air.com

sales@clean-air.com