Clean Air Industries WeldStation EVO User Manual

M ODE S ELECTOR S WITCH

This switch controls the mode of the unit.

The “ Auto ” position sets the WeldStation in

Automatic mode and allows the economizer to function.

The “ 0 ” position stops the WeldStation

operation.

The “ Man. ” position sets the WeldStation into

Manual Override mode and allows and runs the motor without any effects of the economizer

or sleep function.

The optional remote mode switch can be installed to control operation of the mode from a

second location. The unit can be started or stopped from the secondary location, but a

hierarchy for modes is used. The stop function always has highest priority, the manual mode

second, and automatic last. See the wiring diagram for wiring of the remote mode switch

installation.

The Clean Air Economizer TM switch can be installed to control operation of the WeldStation based on welding. Multiple Economizers TM can be wired in parallel. The unit can be started from either location; however, the unit can only be manually stopped by pressing switching the mode to "0". The unit will stop automatically based on the Economizer TM timer. See the

wiring diagram for wiring of the economizer mode switch installation.