Main Screen
Clean Air Industries WeldStation EVO can be controlled with a tablet, or smart phone via the CMT Viewer App. On the home screen, or main screen, you can see an overview of these settings.
1: The Safety indicator monitors the
safety relay circuit in the unit ensuring
that key components only activate when
it is safe to do so. When the safety relay
is inactive, the indicator will turn dark and
the unit will not power on. The safety
relay can be engaged by pressing the
green button
2: The Valve 1 and 2 indicators display in
real time when air is released from the reservoir and into the filters. While the unit is pulsing, the
indicator will light up
3: The Econ indicator will turn green whenever the unit detects welding activities and remain dark when it’s OFF. The unit has to be in Econ Mode, which can be set by turning the three way switch to Auto
4: Filter pressure monitors the differential pressure between the clean and dirty side of the filter. This
value tells the user the status of the filter and whether it needs to be replaced. The pressure readings
are also used to control motor speed and the auto pulsing mode. This is shown graphically by Item #7
5: The alert indicator logs the alert that was triggered. In order to see the displays, a click on top of the alert sign will immediately open the pop up window displaying the events.
6: The high filter pressure indicator shows the state of the filters when it is time to replace the filters.
An email alert will be sent to indicate that it is time to change the filters.
7: This graph shows the value of the filter pressure graphically
8: The motor indicator shows the state of the motor when it is on run mode.
Page 62 of 83
1-866-665-1829
clean-air.com
sales@clean-air.com
Made with FlippingBook - professional solution for displaying marketing and sales documents online