Technical data 4.6/5.0/6.0 kW

Primo GEN24/GEN24 Plus

4.6

5.0

6.0

2

2

2

Number of MPP trackers

DC input voltage range (Udc min - Udc max)

65 - 600

65 - 600

65 - 600

V

400

400

400

Nominal input voltage (Udc,r)

V

Feed-in start-up input voltage (Udc start)

80

80

80

V

65 - 530

65 - 530

65 - 480

Usable MPP voltage range

V

MPP voltage range (at rated power) (Umpp min - Umpp max)

230 - 530

230 - 530

230 - 480

V

MPPT1

MPPT2

MPPT1

MPPT2

MPPT1

MPPT2

22

12

22

12

22

12

Max. usable input current (Idc max)

A

36

19

36

19

36

19

Max. array short circuit current (Isc pv) 1

A

2

2

2

2

2

2

Number of DC connections

MPPT1 MPPT2 Total

MPPT1 MPPT2 Total

MPPT1 MPPT2 Total

4,750

4,750

4,750

5,170

5,170

5,170

6,200

5,760

6,200

Max. usable DC power

W

5,750 4,750 6,900 6,250 5,170 7,500 7,500 5,760 9,000

Max. PV generator output

Wpeak

4,600

5,000

6,000

AC rated power (Pac,r)

W

4,600

5,000

6,000

Apparent power

VA

4,600

5,000

6,000

Max. output power

VA

220 Vac

230 Vac

220 Vac

230 Vac

220 Vac

230 Vac

20.9

20

22.7

21.7

27.3

26.1

Nom. AC output current

A

1~ NPE 220/230 (+20%/-30%)

Grid connection (Uac,r)

V

Frequency (frequency range fmin - fmax)

50/60 (45 - 65)

Hz

< 2

< 2

< 2

Total harmonic distortion

%

0,8 - 1 ind. / cap.

Power factor (cos φ ac,r)

3,000

3,000

3,000

Nom. output power PV Point

VA

1~ NPE 220/230

Grid connection PV Point

V

< 23

< 23

< 23

Switching time

sec.

Full Backup power and battery function only available with GEN24 Plus

Primo GEN24 Plus

4.6

5.0

6.0

4,600

5,000

6,000

Nom. output power Full Backup

VA

1~ NPE 220/230

Grid connection Full Backup

V

< 35

< 35

< 35

Switching time

sec.

1

1

1

Number of DC inputs

22

22

22

Max. input current (Idc max)

A

DC input voltage range (Udc min - Udc max) 3

150 - 455

150 - 455

150 - 455

V

1x BATT+ and 1x BATT- push-in spring terminals 2.5 - 10 mm²

DC battery connection technology

4,750

5,170

6,200

Max. DC input/output power 4

W

4,600

5,000

6,000

Max. charging power for AC coupling4 4

W

BYD Battery-Box Premium HVS/HVM, LG FLEX 6

Compatible batteries 5

1 Isc pv = Isc max >= Isc (STC) x 1,25 according to e.g. IEC 60364-7-712, NEC 2020, AS/NZS 5033:2021. 2 The Full Backup option is available for the Primo GEN24 3.0–6.0 Plus. Additional external components for grid switchover are required for the Full Backup. See the Operating Instructions for further details. 3 AC power derating of the inverter occurs with a DC battery input voltage of 419.7 V and higher 4 Depending on connected battery 5 Depending on the country-specific certification and availability 6 Excluding BYD Battery-Box Premium HVS 10.2, HVS 12.8, HVM 8.3, HVM 22.1 & LG FLEX 17.2