Mole Energy - Surveyors Manual - Digital PDF - AW4

Primo GEN24/GEN24 Plus

4.6

5.0

6.0

530 × 474 × 165

Dimensions (height × width × depth)

mm

15.4/19

15.4/19

15.4/19

Weight (inverter/with packaging)

kg

IP 66

IP 66

IP 66

Protection class

1

1

1

Safety class

< 10

< 10

< 10

Night consumption

W

2/3

2/3

2/3

Overvoltage category (DC/AC) 7

Transformerless

Inverter concept

Active Cooling technology

Cooling

Indoor and outdoor installation

Installation

-40 to +60

-40 to +60

-40 to +60

Ambient temperature range

°C

0 - 100

0 - 100

0 - 100

Permissible humidity

%

< 42

< 42

< 42

Noise emissions

dB (A)

4,000

4,000

4,000

Max. altitude above sea level

m

4x DC+ and 4x DC- push-in spring terminals 2.5 - 10 mm²

DC connection technology PV

3-pin AC push-in spring terminals 2.5 - 10 mm² 3-pin backup power push-in spring terminals 1.5 - 10 mm² 2x PE screw terminals 2.5–16 mm² and 3x 2.5 - 10 mm² IEC 62109, IEC 62909, AS/NZS 4777.2, CEI 0-21, ABNT BNR 16149 und 16150, IEC 62116, IEC 61727, G98/G99

AC connection technology

Certificates and compliance with standards 8

PV Point or Full Backup

Backup power functions9

In accordance with ÖNORM EN ISO 14040 and 14044 (checked by employees from Fraunhofer IZM)

Life cycle analysis

97.6

97.6

97.6

Max. efficiency

%

97.2

97.2

97.1

%

Euro. efficiency ( η EU)

> 99.9

> 99.9

> 99.9

MPP adaptation efficiency

%

Integrated

DC isolation measurement

Operating point shift, power limiter

Overload performance

Integrated

DC disconnector

Integrated

Reverse polarity protection

Fronius Solar.web, Modbus TCP SunSpec, Fronius Solar API (JSON)

WLAN/2 × Ethernet LAN

6 digital inputs 6 digital inputs/outputs

Connection to ripple control receiver, energy management

Integrated

Emergency shut-off (WSD)

Integrated

Datalogger and web server

Modbus RTU SunSpec (third-party provider)/Fronius Smart Meter, battery (GEN24 Plus), Fronius Ohmpilot

2 × RS485

7 In line with IEC 62109-1. Option to retrofit surge protection device DC SPD type 1+2 for 2 MPP trackers available under the following item number: 4,240,313,CK 8 You can find the current certificates under www.fronius.com/primo-gen24-plus-cert 9 Full Backup power and battery function only available with GEN24 Plus

For further information on the availability of the inverters in your country, please visit www.fronius.com.

22