Mole Energy - Surveyors Manual - Digital PDF - AW4

Made in Germany. Designed in Switzerland.

Lead Free

Mechanical specification

1041

Dimensions [mm]

1767 x 1041 x 35

(Distance between mounting and grounding holes) 989 115

26

19.7

Weight [kg] Front cover Back cover

Tempered solar glass, 3.2 mm, with anti-reflective surface

8x3.5 (8x) Drainage holes Ø4.5 (8x) Grounding holes Ø9 (4x) Mounting holes

Black water-barrier backsheet Black anodized aluminum

Frame

Solar cell type Junction boxes

120 half-cells, mono n-Si, HJT with SWCT TM 3 diodes, IP68 rated in accordance with IEC 62790 PV cable 4 mm², 1.2 m length in accordance with EN 50618

Cable

1: MC4; 2: MC4-Evo2; 3: UKT Energy PV-CO02; 4: TE Connectivity PV4-S1 in accordance with IEC 62852, IP68 rated only when connected

Connectors

12

1200 Cable length

Packages

Dimension in mm

35

max. 2 pallets Delivery by container or truck. For truck freight, 0.78 loading meters per pallet and stacking factor 2 apply. 1780 mm 1050 mm 1300 mm 650 kg 28 pallets 30 modules

26 pallets

Electrical specification 1

Power class

Efficiency

Power*

Short circuit current Open circuit voltage Current at MPP

Voltage at MPP

η

P

I sc

V oc [V]

I mpp [A]

V mpp

max

[%]

[W]

[A]

[V]

STC 2 20.4 20.7 20.9 21.2 21.5

STC 375 380 385 390 395

STC 10.6 10.6 10.6 10.6 10.6

STC 44.4 44.5 44.6 44.6 44.7

STC

STC 37.8 38.2 38.5 38.9 39.2

NMOT 3

NMOT

NMOT

NMOT

NMOT

375 380 385 390 395

9.9

283 287 291 294 298

8.5 8.5 8.5 8.5 8.5

42.2 42.2 42.3 42.4 42.4

7.9

35.7 36.1 36.4 36.7 37.0

10.0 10.0 10.1 10.1

8.0 8.0 8.0

8.1

* (Power tolerance -0 W / +5 W for STC)

Temperature coefficients Temperature coefficient of I SC Temperature coefficient of V OC Temperature coefficient of P MPP

I-V curves at different irradiations

α β γ

800 W/m

600 W/m

1200 W/m

400 W/m

1000 W/m (STC)

200 W/m

[%/K] [%/K] [%/K]

+0.033 -0.234 -0.259

12

8

4

[°C]

44±2

Nominal Module Operating Temperature

NMOT 3

0

Voltage (V)

10

20

30

40

50

The temperature coefficients stated are linear values.

Properties for system design

Meyer Burger warranty

Max. system voltage

[V] [A]

1000

100%

98%

2.0% Degradation in 1st year 0.25% Annual degradation 25 years Product & power warranty

20

Overcurrent protection rating

95%

+2%

Max. test load +/- (Safety factor for test load = 1.5)

[Pa] [Pa]

6000/4000 4000/2666

92%

+4%

90%

Max. design load +/-

Safety class

II 5

85%

Fire type (UL 61730)

80%

0

5

10

15

20

25

Years

Fire class (EN 13501-1 / DIN 4102-1)

E/B2/B ROOF (t1)

Operation temperature

[°C]

-40 to +85

Meyer Burger

Market average

Certificates

Certification IEC 61215:2016, IEC 61730:2016, UL 61730-1, UL 61730-2, PID (IEC 62804) Certification (pending) Salt Mist (IEC 61701), Ammonia Resistance (IEC 62716), Dust & Sand (IEC 60068)

Test procedure according to IEC standard 1 IEC 3 IEC Market standard Meyer Burger materials testing

1 Measurement according to IEC 60904-3, measurement tolerance: ±3% 2 STC: Irradiance 1000 W/m², module temperature 25°C, AM1.5G spectrum 3 NMOT: Nominal Module Operating Temperature, with irradiance 800 W/m², AM1.5G Spectrum, ambient temperature 20°C

Notice: All data and specifications are preliminary and subject to change without notice. Visit us at meyerburger.com