Made in Germany. Designed in Switzerland.
Lead Free
Mechanical specification
1041
Dimensions [mm]
1767 x 1041 x 35
(Distance between mounting and grounding holes) 989 115
26
19.7
Weight [kg] Front cover Back cover
Tempered solar glass, 3.2 mm, with anti-reflective surface
8x3.5 (8x) Drainage holes Ø4.5 (8x) Grounding holes Ø9 (4x) Mounting holes
Black water-barrier backsheet Black anodized aluminum
Frame
Solar cell type Junction boxes
120 half-cells, mono n-Si, HJT with SWCT TM 3 diodes, IP68 rated in accordance with IEC 62790 PV cable 4 mm², 1.2 m length in accordance with EN 50618
Cable
1: MC4; 2: MC4-Evo2; 3: UKT Energy PV-CO02; 4: TE Connectivity PV4-S1 in accordance with IEC 62852, IP68 rated only when connected
Connectors
12
1200 Cable length
Packages
Dimension in mm
35
max. 2 pallets Delivery by container or truck. For truck freight, 0.78 loading meters per pallet and stacking factor 2 apply. 1780 mm 1050 mm 1300 mm 650 kg 28 pallets 30 modules
26 pallets
Electrical specification 1
Power class
Efficiency
Power*
Short circuit current Open circuit voltage Current at MPP
Voltage at MPP
η
P
I sc
V oc [V]
I mpp [A]
V mpp
max
[%]
[W]
[A]
[V]
STC 2 20.4 20.7 20.9 21.2 21.5
STC 375 380 385 390 395
STC 10.6 10.6 10.6 10.6 10.6
STC 44.4 44.5 44.6 44.6 44.7
STC
STC 37.8 38.2 38.5 38.9 39.2
NMOT 3
NMOT
NMOT
NMOT
NMOT
375 380 385 390 395
9.9
283 287 291 294 298
8.5 8.5 8.5 8.5 8.5
42.2 42.2 42.3 42.4 42.4
7.9
35.7 36.1 36.4 36.7 37.0
10.0 10.0 10.1 10.1
8.0 8.0 8.0
8.1
* (Power tolerance -0 W / +5 W for STC)
Temperature coefficients Temperature coefficient of I SC Temperature coefficient of V OC Temperature coefficient of P MPP
I-V curves at different irradiations
α β γ
800 W/m
600 W/m
1200 W/m
400 W/m
1000 W/m (STC)
200 W/m
[%/K] [%/K] [%/K]
+0.033 -0.234 -0.259
12
8
4
[°C]
44±2
Nominal Module Operating Temperature
NMOT 3
0
Voltage (V)
10
20
30
40
50
The temperature coefficients stated are linear values.
Properties for system design
Meyer Burger warranty
Max. system voltage
[V] [A]
1000
100%
98%
2.0% Degradation in 1st year 0.25% Annual degradation 25 years Product & power warranty
20
Overcurrent protection rating
95%
+2%
Max. test load +/- (Safety factor for test load = 1.5)
[Pa] [Pa]
6000/4000 4000/2666
92%
+4%
90%
Max. design load +/-
Safety class
II 5
85%
Fire type (UL 61730)
80%
0
5
10
15
20
25
Years
Fire class (EN 13501-1 / DIN 4102-1)
E/B2/B ROOF (t1)
Operation temperature
[°C]
-40 to +85
Meyer Burger
Market average
Certificates
Certification IEC 61215:2016, IEC 61730:2016, UL 61730-1, UL 61730-2, PID (IEC 62804) Certification (pending) Salt Mist (IEC 61701), Ammonia Resistance (IEC 62716), Dust & Sand (IEC 60068)
Test procedure according to IEC standard 1 IEC 3 IEC Market standard Meyer Burger materials testing
1 Measurement according to IEC 60904-3, measurement tolerance: ±3% 2 STC: Irradiance 1000 W/m², module temperature 25°C, AM1.5G spectrum 3 NMOT: Nominal Module Operating Temperature, with irradiance 800 W/m², AM1.5G Spectrum, ambient temperature 20°C
Notice: All data and specifications are preliminary and subject to change without notice. Visit us at meyerburger.com
WEEE Reg. No. DE 18170271
Go Back
7
Made with FlippingBook - professional solution for displaying marketing and sales documents online