42 GATE OPERATION
GATE TROUBLESHOOTING - ELECTRICAL
If the gates do not operate properly, inspect the following components:
ELECTRICAL SYSTEM 1. Check for positive connections at 6 and 7 way receptacles. 2. Check receptacles for damaged pins; repair or replace as needed. 3. With the main power switch in the “On” position, check connection posts on Buss bar for power. 4. Check connection posts on switches for power (a second person is required). 5. Check ground connection in rear void; make sure 7-way connector is plugged into ground unit.
PRESSURE GAUGE
SOLENOIDS
MAIN SOLENOID VALVE
Buss Bar Connections
MAIN VALVE BODY
S - WHITE SEMI OPEN
A - BLACK SEMI CLOSED
LT - YELLOW PUP OPEN
TM - RED MAIN POWER
GD - GREEN NOT USED (SPARE)
RT - BROWN PUP CLOSED
GROUND