GWO BR v2.0

GWO Blade Repair Training Standard V2.0

2021-04-01_TS_BR_V2

VISUAL AND CONDUCTIVITY INSPECTION

Learning objectives:

The participants can imitate how to carry out a visual inspection of the lightning protection system (Skills, basic level) The participants can act independently in identifying damaged components of the lightning protection system by conducting a visual inspection (Ability, intermediate level)

Training staff shall:

Show examples of damaged lightning protection system components

Demonstrate how to carry out a visual inspection of the lightning protection system

Facilitate practice to improve the participants’ ability to identify damaged components of the lightning protection system by conducting a visual inspection

The participants shall:

Practice the ability to identify damaged components of the lightning protection system by conducting a visual inspection

Training staff shall:

Give feedback on the participants’ abilities to identify damaged component s of the lightning protection system by conducting a visual inspection

MEASURE RESISTANCE

Learning objectives:

The participants can perform safe measurements of the conductivity and resistance of a typical lightning protection system using a low-resistance ohmmeter (Skills, intermediate level) The participants can take responsibility for safely using a low-resistance ohmmeter to measure the resistance of the lightning protection system and to identify a defective lightning receptor (Ability, intermediate level)

Training staff shall:

Describe the tools required for measuring the resistance of the lightning protection system

Explain the safety precautions to be adopted for using a low-resistance ohmmeter

Explain common procedures to ensure correct reading and direct contact between receptor surface and low-resistance ohmmeter (e.g. cleaning the receptor) Demonstrate how to safely use a low-resistance ohmmeter to measure the resistance in the entire lightning protection system Demonstrate how to safely use the low-resistance ohmmeter to identify which lightning receptor or section of cable is defective