PAAS SB V5.1

Industrial Grey PVC-U Pipe And Fittings PP-H Valves

PP-H Zero Static Valve Type 519

• Optimised weir offering higher flows than standard diaphragm arrangement • Linear control with new Weir design • integrated lockable handle

• Two coloured position indicator • Smallest Possible deadspace

PP-H Zero Static Valve Type 519  Only Available with IR/ Butt Weld Spigots

IR/BUTT WELD ENDS

SIZE (d)

PN EPDM PTFE/EPDM 20 mm 20 mm 10 167 519 101 167 519 301 25 mm 20 mm 10 167 519 103 167 519 303 25 mm 25 mm 10 167 519 104 167 519 304 32 mm 20 mm 10 167 519 107 167 519 307 32 mm 25 mm 10 167 519 108 167 519 308 32 mm 32 mm 10 167 519 109 167 519 319 40 mm 20 mm 10 167 519 112 167 519 312 50 mm 20 mm 10 167 519 118 167 519 318 50 mm 25 mm 10 167 519 119 167 519 319 50 mm 32 mm 10 167 519 120 167 519 320 63 mm 20 mm 10 167 519 125 167 519 325 63 mm 25 mm 10 167 519 126 167 519 326 63 mm 32 mm 10 167 519 127 167 519 327

What is Dead Leg and how can a zero static valve assist?

Dead Leg is an area of entrapment in a vessel or piping run that could lead to contamination of the product. A dead leg in your system can cause fluid pooling, reduced cleanability and difficult sterilization. By minimizing or eliminating dead legs, you improve the cleanability and sterility of your system, reducing the possibility of contamination.

The Type 519 Zero Static Valve is designed with the weir of the branched valve located directly on the pipe wall of the main line, therefore dead leg is reduced to an absolute minimum increasing the hygiene properties.

PP-H Inline Flow Diverter PP-H

• Incorporated 1/4” MBSP nipples for connection to Enware taps • Spigot ends suitable for IR or Socket Fusion • Creates small pressure differential allowing flow to faucet with minimal pressure loss

SIZE (d)

CODE

32 mm

167 530 144L

40 mm

167 530 145L

What is an Inline Flow Diverter

The IFD is designed to provide high flow from the distribution main through the faucet for constant water movement. The IFD is engineered to create a differential pressure imbalance which forces water through the faucet with minimal pressure loss. Installation of the IFD is in the distribution main and may serve up to three faucets. Incorporation of the IFD, in addition to flexible tubing into the piping system allows for the material and labour savings without the associated hard pipe, fittings and extra valves needed for a traditional loop design.

1300 PIPING (1300 747 464)

V 5.1

PAAS Source Book 113

Made with FlippingBook Online newsletter maker