Industrial Grey PVC-U Pipe And Fittings Level
Guided radar level transmitter type 2291
Applications General – Challenging tank applications where other non-contacting principles fail e.g. ultrasonic or unguided radar Chemical Process Industry – Storage of solvents, chlorine or ammonia. Level detection in reaction vessels or buffer tanks Water Treatment – Pumping stations, sludge handling, drain level monitoring, drink water conditioning vessels
Process liquids Suitable for hydrocarbons, acids and aggressive media
For most non coating liquids, including flammable and fuming fluids Liquids which tend to foam e.g. in acid neutralization applications Features Coated probes available in FEP, PFA or PP Stainless steel rods and rope Guided wave radar (GWR) ATEX & IECEx options Large graphical LCD display 2 wire transmitter
Benefits Most advanced non-contact technology to detect filling level Easy setup and onsite configuration Adaptable thanks to smart setting options Direct contact to process liquid assures even more reliable measurement, even in challenging conditions
TYPE 2291
CODE
2M ROD (1” BSP CONNECTION)
159 300 192
6M CABLE (1” BSP CONNECTION)
159 300 190
Principle: 2291 The GWR type 2291 is mounted on top of a tank vessel and its probe extends to the full depth of the tank. Microwave pulses are sent along the probe at the speed of light. On the surface of the filling a portion of the energy is reflected back to the transmitter. The time delay between transmitting waves and receiving their reflection provides a distance domain value – Distance=(Speed of light x time delay)/2. Additional tank details allow calculations of volume and mass.
1300 PIPING (1300 747 464)
V 5.1
PAAS Source Book 217