Industrial Grey PVC-U Pipe And Fittings Level

Guided radar level transmitter type 2291

Applications  General – Challenging tank applications where other non-contacting principles fail e.g. ultrasonic or unguided radar  Chemical Process Industry – Storage of solvents, chlorine or ammonia. Level detection in reaction vessels or buffer tanks  Water Treatment – Pumping stations, sludge handling, drain level monitoring, drink water conditioning vessels

Process liquids  Suitable for hydrocarbons, acids and aggressive media

 For most non coating liquids, including flammable and fuming fluids  Liquids which tend to foam e.g. in acid neutralization applications Features  Coated probes available in FEP, PFA or PP  Stainless steel rods and rope  Guided wave radar (GWR)  ATEX & IECEx options  Large graphical LCD display  2 wire transmitter

Benefits  Most advanced non-contact technology to detect filling level  Easy setup and onsite configuration  Adaptable thanks to smart setting options  Direct contact to process liquid assures even more reliable measurement, even in challenging conditions

TYPE 2291

CODE

2M ROD (1” BSP CONNECTION)

159 300 192

6M CABLE (1” BSP CONNECTION)

159 300 190

Principle: 2291 The GWR type 2291 is mounted on top of a tank vessel and its probe extends to the full depth of the tank. Microwave pulses are sent along the probe at the speed of light. On the surface of the filling a portion of the energy is reflected back to the transmitter. The time delay between transmitting waves and receiving their reflection provides a distance domain value – Distance=(Speed of light x time delay)/2. Additional tank details allow calculations of volume and mass.

1300 PIPING (1300 747 464)

V 5.1