CLIENT: HY-C
PERFORMED BY: REVIEWED BY: MODEL: DATE: LOCATION: CALIBRATION DUE: CALIBRATION DUE: CALIBRATION DUE:
Ken Slater
PROJECT #:
Brian Ziegler
G102883416
PRODUCT: FC1000
FC1000
SAMPLE ID #: STANDARD(S):
3/27/2016
CSA B415.1
MID
EQUIPMENT
ASSET # - DESCRIPTION: ASSET # - DESCRIPTION: See Appenix C in final report See Appenix C in final report
See Appenix C in final report
ASSET # - DESCRIPTION:
CONDITIONING
SAMPLE CONDITIONING (IF APPLICABLE): NA
AMBIENT TEMPERATURE: NA
Run:
1
Test Duration: Output Category:
224
3
Test Results in Accordance with CSA B415.1-09
LHV Basis
HHV Basis
Overall Efficiency Combustion Efficiency Heat Transfer Efficiency
70.0% 97.1%
75.4% 97.1% 77.6%
72%
Output Rate (kJ/h) Burn Rate (kg/h)
(Btu/h)
49,826
47,265
(lb/h)
3.58
7.89
Input (kJ/h)
(Btu/h)
71,212
67,553
Test Load Weight (dry kg)
dry lb
13.37 18.88 23.27 12.18
29.46
MC wet (%) MC dry (%)
Particulate (g )
CO (g)
590 3.73
Test Duration (h)
Emissions Particulate
CO
g/MJ Output g/kg Dry Fuel
0.07 0.91 3.26 0.15
3.17
44.14 158.07
g/h
2.63 g/min
lb/MM Btu Output
7.37
Air/Fuel Ratio (A/F)
13.52