EPA Method 28 OWHH Testing Parameters
Manufacturer HY-C Model Number FC1000 Test Technician KS
3 1
Category
Run Number
3/27/2017
Test Date
36.66 23.27 13.49
Total Test Fuel Weight (lb) Avg. Test Fuel Moisture (% dry)
Dry fuel load weight (kg)
Test Duration (min) Burn Rate (kg/hr)
224 3.61
Emissions (g)
12.18 Train 2
Beginning Dry Gas Meter Reading (ft3) 0 Final Dry Gas Meter Reading (ft3) 27.55784 27.55678 Average Barometric Pressure (“Hg) 28.91 Average Delta p (inches of water) 0.063 0
Average Gas Velocity in Tunnel (feet/sec) 15 Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm) 713.4088 kJ
Btu
Total Input Total Output
266520 252781 119,496 113336
kW
Output Rate (kJ/hr, BTU/hr, kW)
32,008 0.10191
30358
8.89
Emissions g/MJ
0.4 B415.1-2010 Limit
Emissions lb/MMBtu Input 0.106209 Emissions lb/MMBtu Output 0.236885
0.93 EPA 2015 Proposed Limit
Emissions g/hr 3.261906 Efficiency 44.8%