FC1000/SF1000: EPA 2017 Certification Report

EPA Method 28 OWHH Testing Parameters

Manufacturer HY-C Model Number FC1000 Test Technician KS

3 1

Category

Run Number

3/27/2017

Test Date

36.66 23.27 13.49

Total Test Fuel Weight (lb) Avg. Test Fuel Moisture (% dry)

Dry fuel load weight (kg)

Test Duration (min) Burn Rate (kg/hr)

224 3.61

Emissions (g)

12.18 Train 2

Beginning Dry Gas Meter Reading (ft3) 0 Final Dry Gas Meter Reading (ft3) 27.55784 27.55678 Average Barometric Pressure (“Hg) 28.91 Average Delta p (inches of water) 0.063 0

Average Gas Velocity in Tunnel (feet/sec) 15 Average Gas Flow Rate in Dilution Tunnel (Qsd) (dscfm) 713.4088 kJ

Btu

Total Input Total Output

266520 252781 119,496 113336

kW

Output Rate (kJ/hr, BTU/hr, kW)

32,008 0.10191

30358

8.89

Emissions g/MJ

0.4 B415.1-2010 Limit

Emissions lb/MMBtu Input 0.106209 Emissions lb/MMBtu Output 0.236885

0.93 EPA 2015 Proposed Limit

Emissions g/hr 3.261906 Efficiency 44.8%