FC1000/SF1000: EPA 2017 Certification Report

HY-C Company, LLC

Date: May 11, 2017

Project No. G102883416

Page 6 of 17

II.B INFORMATION LOG II.B(1) TEST STANDARD

From March 27, 2017 through March 30, 2017, the unit was tested for EPA emissions. For Wood Forced-Air Furnaces, the test was conducted in accordance with CSA B415.1- 2010. The fuel used for the test run was Oak cordwood. The applicable EPA regulatory limits are: Step 1 – 2016 – 0.93 lbs/MMBtu Output (0.4 g/MJ) – For furnaces rated less than 65,000 Btu/hr Step 1 – 2017 – 0.93 0.93 lbs/MMBtu Output (0.4 g/MJ) – For furnaces rated more than 65,000 Btu/hr Step 2 – 2020 – 0.15 lbs/MMBtu Output (0.026 g/MJ)

TEST STANDARD 1 – CSA B415.1

All applicable tests were performed in accordance with CSA B415.1 for a forced air furnace. Clause Test Description Results 8.5.1 Appliance Operation – pretest fuel Complies 8.5.2 Appliance Operation – pretest period Complies 8.5.3 Appliance Operation – test fuel loading Complies 8.5.4 Appliance Operation – test fuel sizing Complies 8.5.5 Appliance Operation – test start-up Complies 8.5.6 Appliance Operation – test start-up - EPA Complies 8.5.7 Appliance Operation – data recording period* Complies 8.5.8 Appliance Operation – fuel adjustment NA 8.5.9 Appliance Operation – heat exchange blowers Complies 8.5.10 Appliance Operation – test completion Complies 8.5.11 Appliance Operation – test clean-up Complies Notes: *Tests were recorded at 1-min intervals.

II.B(2) DEVIATION FROM STANDARD METHOD

No deviations from the standards were performed, however, only the applicable sections from each standard were used during all testing.