HY-C Company, LLC
Date: May 11, 2017
Project No. G102883416
Page 7 of 17
II.C SUMMARY OF TEST RESULTS
The appliance tests resulted in the following performance:
Particulate Emissions: 0.198 lbs/MMBtu Output (0.110 g/MJ) Carbon Monoxide Emissions: 2.015 g/min Heating Efficiency: 62.6% (Higher Heating Value Basis)
II.D DESCRIPTION OF TEST RUNS
RUN #1 March 27, 2017. The furnace was set to draw a category 4 draw rate. The combustion blower was turned on. The Test Load weighed 36.66 lbs. and utilized a 9.1 lb. coal bed. The average Btu/hr output was 30,358. Burn time was 3.73 hours. The kg/hr burn rate was 3.613. This test run will be changed to a category 3 as the Btu/hr is lower than required. RUN #2 March 28, 2017. The furnace was set to draw a category 4 draw rate. The combustion blower was turned on. The Test Load weighed 33.21 lbs. and utilized a 8.1 lb. coal bed. The average Btu/hr output was 45,000. Burn time was 3.45 hours. The kg/hr burn rate was 3.496. RUN #3 March 29, 2017. The furnace was set to draw a category 1 draw rate. The combustion blower was turned on and off to maintain the desired heat rate. The Test Load weighed 37.73 lbs. and utilized a 5.5 lb. coal bed. The average Btu/hr output was 16,691. Burn time was 9.65 hours. The kg/hr burn rate was 1.406. RUN #4 March 30, 2017. The furnace was set to draw a category 2 draw rate. The combustion blower was turned on and off to maintain the desired heat rate. The Test Load weighed 36.28 lbs. and utilized a 6.5 lb. coal bed. The average Btu/hr output was 24,701. Burn time was 5.96 hours. The kg/hr burn rate was 2.207.