Project No: G102883416
Manufacturer: HY-C
Model: FC1000
Date:
3/31/2017
Tech:
Weighted Average for Solid Fuel Aired Heating Appliances
CAT Load % Capacity
Tgt Load (Btu/hr)
Act Load (Btu/hr)
Test Duration (Hours)
WoodWt
Q in
Q out
h N
E T
E E Output
E Input
E
(Lb)
(Btu)
(Btu)
(%)
(g)
(g/MJ) (lb/mmbtu) (lb/mmbtu) (g/hr)
<35% of max
I
17,325 16,691
9.65
37.73
254,292
161,068
63.3%
14.79
0.09
0.20
0.13
1.53
35-53% of max 53-76% of max
II
21,780 24,701
5.97
36.28
246,736
147,380
59.7%
11.93
0.08
0.18
0.11
2.00
III
32,175 30,358
3.73
36.66
252,781
113,336
44.8%
12.18
0.10
0.24
0.11
3.26
Max capacity
IV
49,500 45,000
3.45
33.21
226,044
155,250
68.7%
15.79
0.10
0.22
0.15
4.58
Efficiency Efficiency
#DIV/0!
#DIV/0!
Average BTU/hr for 8 hr burn time
#DIV/0!
Y1 Y2 X1 X2 Z1 Z2 Z3 Z4
Test duration above 8 hours Test duration just below 8 hours Actual load (BTU/hr) for duration Y1 Actual load (BTU/hr) for duration Y2 Efficiency for duration Y1 HHV Efficiency for duration Y2 HHV Efficiency for duration Y1 LHV Efficiency for duration Y2 LHV
HHV
LHV
If the test is ASTM put a 0, if EPA put a 1
0
Maximum output rating BTU/hr:
49,500
Weighted Average
Weighting
Direct x F i
Stack Loss
Output
E g/MJ,I x F i x F i
E lb/mmbtu x F i
E g/hr x F i
CO g/hr x F i
CO g/min x F i
Category Factor
I
0.937 0.292 0.055 0.010 1.293
59.284 17.413 3.758 0.452 62.572
0.082 0.022 0.006 0.001 0.110
68.556 20.243 3.545 0.706 71.962
0.189 0.052 0.012 0.002 0.198
1.436 0.583 0.250 0.033 1.781
100.231 46.301
1.671 0.772 0.137 0.027 2.015
II
III IV
8.229 1.593
Totals
120.921
C:\Users\PVanderEems\Documents\Product Development\FC\1000 Series Test Data\Appendix B - Data and Calculation Forms\[Weighted Avg FC1000.xls]Sheet1 Remember to use Paste special when copying to this area, values only!
Weighted Avg FC1000
Made with FlippingBook - professional solution for displaying marketing and sales documents online